NAME
       powercom - UPS driver for serial Powercom/Trust/Advice UPS equipment

NOTE
       This man page only documents the hardware-specific features of the
       powercom driver. For information about the core driver, see
       nutupsdrv(8).

SUPPORTED HARDWARE
       This driver supports many similar kinds of serial UPS hardware (as well
       as a few USB UPS models with USB-to-serial adapters). The most common
       ones are the Trust 425/625, Powercom, and Advice Partner/King PR750.
       Others using the same protocol may also work. For USB connections, you
       might need usbhid-ups(8).

       For more specific guidance on which driver is applicable for a USB
       connection, see the NUT Hardware Compatibility List (HCL).

EXTRA ARGUMENTS
       This driver supports the following optional settings in the ups.conf(5)
       file:

       linevoltage=value
	   An integer specifying the line voltage. It can’t be auto detected.
	   Acceptable values are in the range of 110-120 or 220-240. The
	   default is 230.

       manufacturer=name
	   Specify the manufacturer name, which also can’t be auto detected.
	   This is a user defined string, so any name is acceptable. The
	   default is PowerCom.

       modelname=name
	   Specify the model name, which also can’t be auto detected. This is
	   a user defined string, so any name is acceptable. The default is
	   Unknown.

       serialnumber=value
	   Like modelname above, but for the serial number. The default is
	   Unknown.

       type=name
	   The exact type of the communication protocol within the powercom
	   family, that will be used to communicate with the UPS. The type is
	   named after the first modelname that was coded with that protocol.
	   The acceptable names are Trust, Egys, KP625AP, IMP, KIN, BNT, and
	   BNT-other. The default is Trust.

	   BNT-other is a special type for other BNT models (such as the 1500A
	   at 120V and can be used to override ALL models using ALL of the
	   following values.

       shutdownArguments={{minutes,seconds},whether_minutes_should_be_used}
	   The minutes and seconds that the UPS should wait between receiving
	   the shutdown command and actually shutting off. The other argument
	   should be set to the character n only when the minutes value should
	   be skipped and not sent to the UPS. The default is type-dependent
	   and is given below. The braces and commas are mandatory. Note that
	   there should be no whitespace characters.

       numOfBytesFromUPS=value
	   The number of bytes in a UPS frame: 16 is common, 11 for Trust. The
	   default is type-dependent and is given below.

       methodOfFlowControl=name
	   The method of serial communication flow control that is engaged by
	   the UPS. The default is type-dependent and is given below.
	   Acceptable names are dtr0rts1, dtr1 or no_flow_control.

       validationSequence={{index1,value1},{index2,value2},{index3,value3}}
	   (Only for types KP625AP, Trust, Egys.) 3 pairs to be used for
	   validating the UPS by comparing bytes of the raw data with constant
	   values. The index selects the byte from the UPS (see
	   numOfBytesFromUPS) and the value is for matching to the byte. The
	   default is type-dependent and is given below. The braces and commas
	   are mandatory, as the lack of white space characters.

       frequency={A,B}
	   (Only for types KP625AP, Trust, Egys.) A pair to convert the raw
	   frequency data to a human-readable frequency reading using the
	   function 1/(A*x+B). If the raw value x IS the frequency, then set
	   A=1/(x^2) and B=0. The default is type-dependent and is given
	   below. Do note that the braces and commas are mandatory as well, as
	   the lack of whitespace characters.

       loadPercentage={BatteryA,BatteryB,LineA,LineB}
	   (Only for types KP625AP, Trust, Egys.) A quad to convert the raw
	   load data to human readable load percentage reading using the
	   function A*x+B. If the raw value x IS the Load Percent, then set
	   A=1 and B=0. The default is type-dependent and is given below. Do
	   note that the braces and commas are mandatory, as the lack of white
	   space characters.

       batteryPercentage={Battery1,Battery2,Battery3,Line4,Line5}
	   (Only for KP625AP, Trust, Egys.) A 5 tuple to convert the raw
	   battery and line data to a human-readable battery and line
	   percentage reading using the functions (Battery) A*x+B*y+C and
	   (Line) D*x+E. If the raw value x IS the Battery Percent, then set
	   A=1, B=0, C=0, D=1, E=0. The default is type-dependent and is given
	   below. Do note that the braces and commas are mandatory, as the
	   lack of white space characters.

       voltage={240A,240B,120A,120B}
	   (Only for types KP625AP, Trust, Egys.) A quad that is used convert
	   the raw voltage data to a human-readable voltage reading using the
	   function A*x+B. If the raw value x IS HALF the Voltage, then set
	   A=2, B=0. The default is type-dependent and is given below. Do note
	   that the braces and commas are mandatory, as well as the lack of
	   whitespace characters.

DEFAULT VALUES FOR THE EXTRA ARGUMENTS
	   linevoltage = 230
	   manufacturer = PowerCom
	   modelname = Unknown
	   serialnumber = Unknown
	   type = Trust

       The rest of the default values for the extra arguments are
       type-dependent. However, BNT-other is a special type that can be used
       to override ALL values for ALL models.

   Trust
	   numOfBytesFromUPS = 11
	   methodOfFlowControl = dtr0rts1
	   validationSequence = {{5,0},{7,0},{8,0}}
	   shutdownArguments = {{0,10},n}
	   frequency = {0.00020997,0.00020928}
	   loadPercentage = {6.1343,-0.3808,4.3110,0.1811}
	   batteryPercentage = {5.0000,0.3268,-825.00,4.5639,-835.82}
	   voltage = {1.9216,-0.0977,0.9545,0.0000}

   KP625AP
	   numOfBytesFromUPS = 16
	   methodOfFlowControl = dtr0rts1
	   validationSequence = {{5,0x80},{7,0},{8,0}}
	   shutdownArguments = {{0,10},n}
	   frequency = {0.00020997,0.00020928}
	   loadPercentage = {6.1343,-0.3808,4.3110,0.1811}
	   batteryPercentage = {5.0000,0.3268,-825.00,4.5639,-835.82}
	   voltage = {1.9216,-0.0977,0.9545,0.0000}

   Egys
	   numOfBytesFromUPS = 16
	   methodOfFlowControl = no_flow_control
	   validationSequence = {{5,0x80},{7,0},{8,0}}
	   shutdownArguments = {{0,10},n}
	   frequency = {0.00020997,0.00020928}
	   loadPercentage = {6.1343,-0.3808,1.3333,0.6667}
	   batteryPercentage = {5.0000,0.3268,-825.00,2.2105,-355.37}
	   voltage = {1.9216,-0.0977,0.9545,0.0000}

   IMP
	   numOfBytesFromUPS = 16
	   methodOfFlowControl = no_flow_control
	   validationSequence = {{5,0xFF},{7,0},{8,0}}
	   shutdownArguments = {{1,30},y}

   KIN
	   numOfBytesFromUPS = 16
	   methodOfFlowControl = no_flow_control
	   validationSequence = {{11,0x4b},{8,0},{8,0}}
	   shutdownArguments = {{1,30},y}

   BNT
	   numOfBytesFromUPS = 16
	   methodOfFlowControl = no_flow_control
	   validationSequence = {{11,0x42},{8,0},{8,0}}
	   shutdownArguments = {{1,30},y}

   BNT-other
	   numOfBytesFromUPS = 16
	   methodOfFlowControl = no_flow_control
	   validationSequence = {{8,0},{8,0},{8,0}}
	   shutdownArguments = {{1,30},y}
	   frequency = {0.00027778,0.0000}
	   loadPercentage = {1.0000,0.0,1.0000,0.0}
	   batteryPercentage = {1.0000,0.0000,0.0000,1.0000,0.0000}
	   voltage = {2.0000,0.0000,2.0000,0.0000}

AUTHOR
       Peter Bieringer <pb@bieringer.de>, Alexey Sidorov
       <alexsid@altlinux.org>, Keven L. Ates <atescomp@gmail.com>

SEE ALSO
   The core driver:
       nutupsdrv(8)

   Internet resources:
       The NUT (Network UPS Tools) home page: http://www.networkupstools.org/

Network UPS Tools		  08/07/2012			   POWERCOM(8)
[top]

List of man pages available for Mageia

Copyright (c) for man pages and the logo by the respective OS vendor.

For those who want to learn more, the polarhome community provides shell access and support.

[legal] [privacy] [GNU] [policy] [cookies] [netiquette] [sponsors] [FAQ]
Tweet
Polarhome, production since 1999.
Member of Polarhome portal.
Based on Fawad Halim's script.
....................................................................
Vote for polarhome
Free Shell Accounts :: the biggest list on the net