VMS Help INITIALIZE, /QUEUE, Qualifiers *Conan The Librarian (sorry for the slow response - running on an old VAX) |
1 - /AUTOSTART_ON
/AUTOSTART_ON=(node::[device][,...]) Designates the queue as an autostart execution queue and specifies the node, or node and device, on which the queue can be located. For batch queues, only node is applicable. In a cluster, you can specify more than one node (or node and device) on which a queue can run, in the preferred order in which nodes should claim the queue. This allows the queue to fail over to another node if the node on which the queue is running leaves the cluster. When you enter the INITIALIZE/QUEUE command with the /AUTOSTART_ ON qualifier, you must initially activate the queue for autostart, either by specifying the /START qualifier with the INITIALIZE/QUEUE command or by entering a START/QUEUE command. However, the queue will not begin processing jobs until the ENABLE AUTOSTART/QUEUES command is entered for a node on which the queue can run. This qualifier cannot be used in conjunction with the /ON or /GENERIC qualifier. However, if you are reinitializing an existing queue, you can specify the /AUTOSTART_ON qualifier for a queue previously created or started with the /ON qualifier. Doing so overrides the /ON qualifier and makes the queue an autostart queue. For more information about autostart queues, refer to the chapter about queues in OpenVMS System Manager's Manual, Volume 1: Essentials.
2 - /BASE_PRIORITY
/BASE_PRIORITY=n Specifies the base process priority at which jobs are initiated from a batch execution queue. By default, if you omit the qualifier, jobs are initiated at the same priority as the base priority established by DEFPRI at system generation (usually 4). The base priority specifier can be any decimal value from 0 to 15. You also can specify this qualifier for an output execution queue. In this context the /BASE_PRIORITY qualifier establishes the base priority of the symbiont process when the symbiont process is created.
3 - /BATCH
/BATCH /NOBATCH (default) Specifies that you are initializing a batch queue. If you are reinitializing an existing queue, you can use the /BATCH qualifier only if the queue was created as a batch queue. A batch queue is classified as either an execution queue or a generic queue. By default, the /BATCH qualifier initializes an execution queue. To specify a generic batch queue, use the /GENERIC qualifier together with the /BATCH qualifier. The /BATCH and /DEVICE qualifiers are mutually exclusive; the /NOBATCH and /NODEVICE qualifiers cannot be used together.
4 - /BLOCK_LIMIT
/BLOCK_LIMIT=([lowlim,]uplim) /NOBLOCK_LIMIT (default) Limits the size of print jobs that can be processed on an output execution queue. The /BLOCK_LIMIT qualifier allows you to reserve certain printers for certain size jobs. You must specify at least one of the parameters. The lowlim parameter is a decimal number referring to the minimum number of blocks accepted by the queue for a print job. If a print job is submitted that contains fewer blocks than the lowlim value, the job remains pending until the block limit for the queue is changed. After the block limit for the queue is decreased sufficiently, the job is processed. The uplim parameter is a decimal number referring to the maximum number of blocks that the queue accepts for a print job. If a print job is submitted that exceeds this value, the job remains pending until the block limit for the queue is changed. After the block limit for the queue is increased sufficiently, the job is processed. If you specify only an upper limit for jobs, you can omit the parentheses. For example, /BLOCK_LIMIT=1000 means that only jobs with 1000 blocks or less are processed in the queue. To specify only a lower job limit, you must use a null string ("") to indicate the upper specifier. For example, /BLOCK_LIMIT=(500,"") means any job with 500 or more blocks is processed in the queue. You can specify both a lower and upper limit. For example, /BLOCK_LIMIT=(200,2000) means that jobs with less than 200 blocks or more than 2000 blocks are not processed in the queue. The /NOBLOCK_LIMIT qualifier cancels the previous setting established by the /BLOCK_LIMIT qualifier for that queue.
5 - /CHARACTERISTICS
/CHARACTERISTICS=(characteristic[,...]) /NOCHARACTERISTICS (default) Specifies one or more characteristics for processing jobs on an execution queue. If you specify only one characteristic, you can omit the parentheses. If a queue does not have all the characteristics that have been specified for a job, the job remains pending. Each time you specify the /CHARACTERISTICS qualifier, all previously set characteristics are cancelled. Only the characteristics specified with the qualifier are established for the queue. Queue characteristics are installation specific. The characteristic parameter can be either a value from 0 to 127 or a characteristic name that has been defined by the DEFINE/CHARACTERISTIC command. The /NOCHARACTERISTICS qualifier cancels any settings previously established by the /CHARACTERISTICS qualifier for that queue.
6 - /CLOSE
Prevents jobs from being entered in the queue through PRINT or SUBMIT commands or as a result of requeue operations. To allow jobs to be entered, use the /OPEN qualifier. Whether a queue accepts or rejects new job entries is independent of the queue's state (such as paused, stopped, or stalled). When a queue is marked closed, jobs executing continue to execute. Jobs pending in the queue continue to be candidates for execution.
7 - /CPUDEFAULT
/CPUDEFAULT=time Defines the default CPU time limit for all jobs in this batch execution queue. You can specify time as delta time, 0, INFINITE, or NONE (default). You can specify up to 497 days of delta time. If the queue does not have a specified CPUMAXIMUM time limit and the value established in the user authorization file (UAF) has a specified CPU time limit of NONE, either the value 0 or the keyword INFINITE allows unlimited CPU time. If you specify NONE, the CPU time value defaults to the value specified either in the UAF or by the SUBMIT command (if included). CPU time values must be greater than or equal to the number specified by the system parameter PQL_MCPULM. The time cannot exceed the CPU time limit set by the /CPUMAXIMUM qualifier. For information on specifying delta time, refer to the OpenVMS User's Manual or the online help topic DCL_Tips (subtopic Date_Time).
8 - /CPUMAXIMUM
/CPUMAXIMUM=time Defines the maximum CPU time limit for all jobs in a batch execution queue. You can specify time as delta time, 0, INFINITE, or NONE (default). You can specify up to 497 days of delta time. The /CPUMAXIMUM qualifier overrides the time limit specified in the user authorization file (UAF) for any user submitting a job to the queue. Either the value 0 or the keyword INFINITE allows unlimited CPU time. If you specify NONE, the CPU time value defaults to the value specified either in the UAF or by the SUBMIT command (if included). CPU time values must be greater than or equal to the number specified by the system parameter PQL_MCPULM. For information on specifying delta times, refer to the OpenVMS User's Manual or the online help topic DCL_Tips (subtopic Date_ Time). A CPU time limit for processes is specified by each user record in the system UAF. You also can specify the following: a default CPU time limit or a maximum CPU time limit for all jobs in a given queue, or a default CPU time limit for individual jobs in the queue. The following table shows the action taken for each value specified and possible combinations of specifications. Default CPU Time CPU Time Maximum CPU Limit Limit Time Limit Specified by Specified Specified the SUBMIT for the for the Command? Queue? Queue? Action Taken No No No Use the UAF value. Yes No No Use the smaller of SUBMIT command and UAF values. Yes Yes No Use the smaller of SUBMIT command and UAF values. Yes No Yes Use the smaller of SUBMIT command and queue's maximum values. Yes Yes Yes Use the smaller of SUBMIT command and queue's maximum values. No Yes Yes Use the smaller of queue's default and maximum values. No No Yes Use the maximum value. No Yes No Use the smaller of UAF and queue's default values.
9 - /DEFAULT
/DEFAULT=(option[,...]) /NODEFAULT Establishes defaults for certain options of the PRINT command. Defaults are specified by the list of options. If you specify only one option, you can omit the parentheses. After you set an option for the queue with the /DEFAULT qualifier, you do not have to specify that option in your PRINT command. If you do specify these options in your PRINT command, the values specified with the PRINT command override the values established for the queue with the /DEFAULT qualifier. You cannot use the /DEFAULT qualifier with the /GENERIC qualifier. Possible options are as follows: [NO]BURST[=keyword] Controls whether two file flag pages with a burst bar between them are printed preceding output. If you specify the value ALL (default), these flag pages are printed before each file in the job. If you specify the value ONE, these flag pages are printed once before the first file in the job. [NO]FEED Controls whether a form feed is inserted automatically at the end of a page. [NO]FLAG[=keyword] Controls whether a file flag page is printed preceding output. If you specify the value ALL (default), a file flag page is printed before each file in the job. If you specify the value ONE, a file flag page is printed once before the first file in the job. FORM=type Specifies the default form for an output execution queue. If a job is submitted without an explicit form definition, this form is used to process the job. If no form type is explicitly specified with the FORM keyword, the system assigns the form DEFAULT to the queue. See also the description of the /FORM_MOUNTED=type qualifier. [NO]TRAILER[=keyword] Controls whether a file trailer page is printed following output. If you specify the value ALL (default), a file trailer page is printed after each file in the job. If you specify the value ONE, a trailer page is printed once after the last file in the job. When you specify the BURST option for a file, the [NO]FLAG option does not add or subtract a flag page from the two flag pages that are printed preceding the file. For information on establishing mandatory queue options, see the description of the /SEPARATE qualifier. For more information on specifying default queue options, refer to the chapter on queues in the OpenVMS System Manager's Manual.
10 - /DESCRIPTION
/DESCRIPTION=string /NODESCRIPTION (default) Specifies a string of up to 255 characters used to provide operator-supplied information about the queue. Enclose strings containing lowercase letters, blanks, or other nonalphanumeric characters (including spaces) in quotation marks (" "). The /NODESCRIPTION qualifier removes any descriptive text that may be associated with the queue.
11 - /DEVICE
/DEVICE[=option] /NODEVICE Specifies that you are initializing an output queue of a particular type. If you are reinitializing an existing queue, you can use the /DEVICE qualifier only if the queue was created as an output queue. Possible options are as follows: PRINTER Indicates a printer queue. SERVER Indicates a server queue. A server queue is controlled by the user-modified or user-written symbiont specified with the /PROCESSOR qualifier. TERMINAL Indicates a terminal queue. If you specify the /DEVICE qualifier without a queue type, the /DEVICE=PRINTER qualifier is used by default. An output queue is classified as either an execution or generic queue. By default, the /DEVICE qualifier initializes an execution queue of the designated type. To specify a generic printer, server, or terminal queue, use the /GENERIC qualifier with the /DEVICE qualifier. You specify the queue type with the /DEVICE qualifier for informational purposes. When an output execution queue is started, the symbiont associated with the queue determines the actual queue type. The standard symbiont examines device characteristics to establish whether the queue should be marked as printer or terminal. By convention, user-modified and user- written symbionts mark the queue as a server queue. The device type of a generic queue need not match the device type of its execution queues. The /DEVICE and /BATCH qualifiers are mutually exclusive; the /NODEVICE and /NOBATCH qualifiers cannot be used together.
12 - /DISABLE_SWAPPING
/DISABLE_SWAPPING /NODISABLE_SWAPPING (default) Controls whether batch jobs executed from a queue can be swapped in and out of memory.
13 - /ENABLE_GENERIC
/ENABLE_GENERIC (default) /NOENABLE_GENERIC Specifies whether files queued to a generic queue that does not specify explicit queue names with the /GENERIC qualifier can be placed in this execution queue for processing. For more information, see the description of the /GENERIC qualifier.
14 - /FORM_MOUNTED
/FORM_MOUNTED=type Specifies the mounted form for an output execution queue. If no form type is explicitly specified, the system assigns the form DEFAULT to the queue. If the stock of the mounted form does not match the stock of the default form, as indicated by the /DEFAULT=FORM qualifier, all jobs submitted to this queue without an explicit form definition enter a pending state and remains pending until the stock of the mounted form of the queue is identical to the stock of the form associated with the job. If a job is submitted with an explicit form and the stock of the explicit form is not identical to the stock of the mounted form, the job enters a pending state and remains pending until the stock of the mounted form of the queue is identical to the stock of the form associated with the job. To specify the form type, use either a numeric value or a form name that has been defined by the DEFINE/FORM command. Form types are installation-specific. You cannot use the /FORM_MOUNTED qualifier with the /GENERIC qualifier.
15 - /GENERIC
/GENERIC[=(queue-name[,...])] /NOGENERIC (default) Specifies a generic queue. Also specifies that jobs placed in this queue can be moved for processing to compatible execution queues. The /GENERIC qualifier optionally accepts a list of target execution queues that have been previously defined. For a generic batch queue, these target queues must be batch execution queues. For a generic output queue, these target queues must be output execution queues, but can be of any type (printer, server, or terminal). For example, a generic printer queue can feed a mixture of printer and terminal execution queues. If you do not specify any target execution queues with the /GENERIC qualifier, jobs can be moved to any execution queue that (1) is initialized with the /ENABLE_GENERIC qualifier, and (2) is the same type (batch or output) as the generic queue. To define the queue as a generic batch or output queue, you use the /GENERIC qualifier with either the /BATCH or the /DEVICE qualifier. If you specify neither /BATCH nor /DEVICE on creation of a generic queue, the queue becomes a generic printer queue by default. You cannot use the /SEPARATE qualifier with the /GENERIC qualifier.
16 - /JOB_LIMIT
/JOB_LIMIT=n Indicates the number of batch jobs that can be executed concurrently from the queue. Specify a number in the range 1 to 255. The job limit default value for n is 1.
17 - /LIBRARY
/LIBRARY=filename /NOLIBRARY Specifies the file name for the device control library. When you initialize an output execution queue, you can use the /LIBRARY qualifier to specify an alternate device control library. The default library is SYS$LIBRARY:SYSDEVCTL.TLB. You can use only a file name as the parameter of the /LIBRARY qualifier. The system always assumes that the file is located in SYS$LIBRARY and that the file type is .TLB.
18 - /NAME_OF_MANAGER
/NAME_OF_MANAGER=name Identifies the name of the queue manager to control the queue. Once the queue is created, the queue manager assignment may not be altered. If the /NAME_OF_MANAGER qualifier is omitted, then the default name SYS$QUEUE_MANAGER is used. If the INITIALIZE/QUEUE command is used to modify a queue, and that queue is not controlled by the default queue manager, then the name of the controlling queue manager should be specified with the /NAME_OF_MANAGER qualifier. Alternately, the logical name SYS$QUEUE_MANAGER can be defined to be the correct queue manager, making that queue manager the default for the current process.
19 - /NO_INITIAL_FF
/NO_INITIAL_FF /NONO_INITIAL_FF (default) Allows user to specify whether a form feed should be sent to a printer device when a queue starts. To suppress the initial form feed, use the /NO_INITIAL_FF qualifier. The /NONO_INITIAL_FF qualifier sends a form feed to the output device to ensure the paper is at the top of a page before printing begins.
20 - /ON
/ON=[node::]device[:] (printer, terminal, server queue) /ON=node:: (batch queue) Specifies the node or device, or both, on which this execution queue is located. For batch execution queues, you can specify only the node name. For output execution queues, you can include both the node name and the device name. By default, a queue executes on the same node from which you start the queue. The default device parameter is the same as the queue name. The node name is used in OpenVMS Cluster systems; it must match the node name specified by the system parameter SCSNODE for the OpenVMS computer on which the queue executes. You cannot use the /ON qualifier with the /AUTOSTART_ON or /GENERIC qualifier; however, if you are reinitializing an existing queue, you can specify the /ON qualifier for a queue previously created or started with the /AUTOSTART_ON qualifier. Doing so overrides the /AUTOSTART_ON option and makes the queue a nonautostart queue.
21 - /OPEN
/OPEN (default) Allows jobs to be entered in the queue through PRINT or SUBMIT commands or as the result of requeue operations. To prevent jobs from being entered in the queue, use the /CLOSE qualifier. Whether a queue accepts or rejects new job entries is independent of the queue's state (such as paused, stopped, or stalled).
22 - /OWNER_UIC
/OWNER_UIC=uic Enables you to change the user identification code (UIC) of the queue. Specify the UIC by using standard UIC format as described in the OpenVMS Guide to System Security. The default UIC is [1,4].
23 - /PROCESSOR
/PROCESSOR=filename /NOPROCESSOR Allows you to specify your own print symbiont for an output execution queue. You can use any valid file name as a parameter of the /PROCESSOR qualifier. The system supplies the device and directory name SYS$SYSTEM and the file type .EXE. If you use this qualifier for an output queue, it specifies that the symbiont image to be executed is SYS$SYSTEM:filename.EXE. By default, SYS$SYSTEM:PRTSMB.EXE is the symbiont image associated with an output execution queue. The /NOPROCESSOR qualifier cancels any previous setting established with the /PROCESSOR qualifier and causes SYS$SYSTEM:PRTSMB.EXE to be used.
24 - /PROTECTION
/PROTECTION=(ownership[:access],...) Specifies the protection of the queue: o Specify the ownership parameter as system (S), owner (O), group (G), or world (W). o Specify the access parameter as read (R), submit (S), manage (M), or delete (D). A null access specification means no access. The default protection is (SYSTEM:M, OWNER:D, GROUP:R, WORLD:S). If you include only one protection code, you can omit the parentheses. For more information on specifying protection codes, refer to the OpenVMS Guide to System Security. For more information on controlling queue operations through UIC-based protection, refer to the chapter on queues in the OpenVMS System Manager's Manual.
25 - /RECORD_BLOCKING
/RECORD_BLOCKING (default) /NORECORD_BLOCKING Determines whether the symbiont can concatenate (or block together) output records for transmission to the output device. If you specify the /NORECORD_BLOCKING qualifier, the symbiont sends each formatted record in a separate I/O request to the output device. For the standard OpenVMS print symbiont, record blocking can have a significant performance advantage over single-record mode.
26 - /RETAIN
/RETAIN[=option] /NORETAIN (default) Holds jobs in the queue in a retained state after they have executed. The /NORETAIN qualifier enables you to reset the queue to the default. Possible options are as follows: ALL Holds all jobs in the queue after execution. (default) ERROR Holds in the queue only jobs that complete unsuccessfully. A user can request a job retention option for a job by specifying the /RETAIN qualifier with the PRINT, SUBMIT, or SET ENTRY command; however, the job retention option you specify for a queue overrides any job retention option requested by a user for a job in that queue.
27 - /SCHEDULE
/SCHEDULE=SIZE (default) /SCHEDULE=NOSIZE Specifies whether pending jobs in an output execution queue are scheduled for printing based on the size of the job. When the default qualifier /SCHEDULE=SIZE is in effect, shorter jobs print before longer ones. When the /SCHEDULE=NOSIZE qualifier is in effect, jobs are not scheduled according to size. If you enter this command while there are pending jobs in any queue, its effect on future jobs is unpredictable.
28 - /SEPARATE
/SEPARATE=(option[,...]) /NOSEPARATE (default) Specifies the mandatory queue options, or job separation options, for an output execution queue. Job separation options cannot be overridden by the PRINT command. You cannot use the /SEPARATE qualifier with the /GENERIC qualifier. The job separation options are as follows: [NO]BURST Specifies whether two job flag pages with a burst bar between them are printed at the beginning of each job. [NO]FLAG Specifies whether a job flag page is printed at the beginning of each job. [NO]TRAILER Specifies whether a job trailer page is printed at the end of each job. [NO]RESET=(module[,...]Specifies one or more device control library modules that contain the job reset sequence for the queue. The specified modules from the queue's device control library (by default SYS$LIBRARY:SYSDEVCTL) are used to reset the device at the end of each job. The RESET sequence occurs after any file trailer and before any job trailer. Thus, all job separation pages are printed when the device is in its RESET state. When you specify the /SEPARATE=BURST qualifier, the [NO]FLAG separation option does not add or subtract a flag page from the two flag pages that are printed preceding the job. For information on establishing queue options that can be overridden, see the description of the /DEFAULT qualifier. For more information on specifying mandatory queue options, refer to the chapter on queues in the OpenVMS System Manager's Manual.
29 - /START
/START /NOSTART (default) Starts the queue being initialized by the current INITIALIZE/QUEUE command. For autostart queues, this qualifier activates the queue for autostart. The queue begins processing jobs when autostart is enabled with the ENABLE AUTOSTART/QUEUES command on any node on which the queue can run.
30 - /WSDEFAULT
/WSDEFAULT=n Defines for a batch job a working set default, the default number of physical pages that the job can use. The value set by this qualifier overrides the value defined in the user authorization file (UAF) of any user submitting a job to the queue. Specify the value of n as a number of 512-byte pagelets on Alpha systems or 512-byte pages on VAX. Note that OpenVMS rounds this value up to the nearest CPU-specific page so that the actual amount of physical memory allowed may be larger than the specified amount on Alpha. For further information, refer to the OpenVMS System Manager's Manual. If you specify 0 or NONE, the working set default value defaults to the value specified in the UAF or by the SUBMIT command (if it includes a WSDEFAULT value). You also can specify this qualifier for an output execution queue. Used in this context, the /WSDEFAULT qualifier establishes the working set default of the symbiont process for an output execution queue when the symbiont process is created.
31 - /WSEXTENT
/WSEXTENT=n Defines for the batch job a working set extent, the maximum amount of physical memory that the job can use. The job only uses the maximum amount of physical memory when the system has excess free pages. The value set by this qualifier overrides the value defined in the user authorization file (UAF) of any user submitting a job to the queue. Specify the value of n as a number of 512-byte pagelets on Alpha or and 512-byte pages on VAX. Note that OpenVMS rounds this value up to the nearest CPU-specific page so that the actual amount of physical memory allowed may be larger than the specified amount on Alpha. If you specify 0 or NONE, the working set extent value defaults to the value specified in the UAF or by the SUBMIT command (if it includes a WSEXTENT value). You also can specify this qualifier for an output execution queue. Used in this context, the /WSEXTENT qualifier establishes the working set extent of the symbiont process for an output execution queue when the symbiont process is created.
32 - /WSQUOTA
/WSQUOTA=n Defines for a batch job a working set quota, the amount of physical memory that is guaranteed to the job. The value set by this qualifier overrides the value defined in the user authorization file (UAF) of any user submitting a job to the queue. Specify the value of n as a number of 512-byte pagelets on OpenVMS Alpha or 512-byte pages on OpenVMS VAX. OpenVMS rounds this value up to the nearest CPU-specific page so that the actual amount of physical memory allowed may be larger than the specified amount on OpenVMS Alpha. For further information, refer to the OpenVMS System Manager's Manual. If you specify 0 or NONE, the working set quota value defaults to the value specified in the UAF or by the SUBMIT command (if it includes a WSQUOTA value). You also can specify this qualifier for an output execution queue. Used in this context, the /WSQUOTA qualifier establishes the working set quota of the symbiont process for an output execution queue when the symbiont process is created. Working set default, working set quota, and working set extent values are included in each user record in the system UAF. You can specify working set values for individual jobs or for all jobs in a given queue. The decision table shows the action taken for different combinations of specifications that involve working set values. Is the SUBMIT Is the command value queue value specified? specified? Action taken No No Use the UAF value. No Yes Use value for the queue. Yes Yes Use smaller of the two values. Yes No Compare specified value with UAF value; use the smaller.
|