Library /sys$common/syshlp/sysgen.hlb
SHOW, /CONFIGURATION, Examples

 *Conan The Librarian (sorry for the slow response - running on an old VAX)

    1.SYSGEN> SHOW/CONFIGURATION

      This command displays the current system I/O database. The
      following example illustrates a typical display produced by
      this command on VS3100 and 6000-400 systems:

         System CSR and Vectors on 23-OCT-2000 16:39:28.74
         Name: OPA  Units: 1  Nexus:0    (410)
         Name: PKB  Units: 1  Nexus:0    (410)
         Name: TTA  Units: 4  Nexus:0    (410)
         Name: PKA  Units: 1  Nexus:0    (410)
         Name: ESA  Units: 3  Nexus:0    (410)
         Name: GCA  Units: 1  Nexus:0    (410)

         System CSR and Vectors on 23-OCT-2000 16:31:47.12
         Name: PAA  Units: 1  Nexus:48   (CI )
         Name: PAB  Units: 1  Nexus:64   (CI )
         Name: PAC  Units: 1  Nexus:64   (CI )
         Name: PAD  Units: 1  Nexus:176  (CI )
         Name: FXA  Units: 2  Nexus:192  (GXM)
         Name: ETA  Units: 3  Nexus:213  (BVP)
         Name: PAE  Units: 1  Nexus:228  (CI )
         Name: PBA  Units: 1  Nexus:237  (BVP)
         Name: TXA  Units: 16 Nexus:211  (DMB)

    2.SYSGEN> SHOW/CONFIGURATION/COMMAND_FILE/OUTPUT=CONFIG.COM

      This command formats all device data into
      CONNECT/ADAPTER=adapter-spec commands and writes the commands
      to the command file CONFIG.COM. The following example is a
      typical command file produced by this command:

        $ RUN SYS$SYSTEM:SYSGEN
        AUTOCONFIGURE 4
        AUTOCONFIGURE 5
        CONNECT DMA0 /ADAP=8 /CSR=%O777440 /VECT=%O210 /NUMV=01 /DRIVER=DMDRIVER
        CONNECT DMA1 /ADAP=8 /CSR=%O777440 /VECT=%O210 /NUMV=01 /DRIVER=DMDRIVER
        CONNECT LPA0 /ADAP=8 /CSR=%O777514 /VECT=%O200 /NUMV=01 /DRIVER=LPDRIVER
        CONNECT DYA0 /ADAP=8 /CSR=%O777170 /VECT=%O264 /NUMV=01 /DRIVER=DYDRIVER
        CONNECT DYA1 /ADAP=8 /CSR=%O777170 /VECT=%O264 /NUMV=01 /DRIVER=DYDRIVER
        CONNECT XMA0 /ADAP=8 /CSR=%O760070 /VECT=%O300 /NUMV=02 /DRIVER=XMDRIVER
        CONNECT XMB0 /ADAP=8 /CSR=%O760100 /VECT=%O310 /NUMV=02 /DRIVER=XMDRIVER
        CONNECT XMC0 /ADAP=8 /CSR=%O760110 /VECT=%O320 /NUMV=02 /DRIVER=XMDRIVER
        CONNECT TTA0 /ADAP=8 /CSR=%O760130 /VECT=%O330 /NUMV=02 /DRIVER=DZDRIVER
        CONNECT TTA1 /ADAP=8 /CSR=%O760130 /VECT=%O330 /NUMV=02 /DRIVER=DZDRIVER
        CONNECT TTA2 /ADAP=8 /CSR=%O760130 /VECT=%O330 /NUMV=02 /DRIVER=DZDRIVER
        .
        .
        .
        CONNECT TTF7 /ADAP=8 /CSR=%O760200 /VECT=%O400 /NUMV=02 /DRIVER=DZDRIVER