Library /sys$common/syshlp/ncphelp.hlb
LOOP, LINE

 *Conan The Librarian (sorry for the slow response - running on an old VAX)

 Use the LOOP LINE command to initiate loopback testing of X.25 lines
 only.  The parameters are optional and can be entered in any order.
 Before beginning loopback testing of an X.25 line, use the SET LINE
 command to set the STATE, SERVICE and CONTROLLER LOOPBACK parameters
 for internal loopback testing or the STATE SERVICE and CONTROLLER
 NORMAL parameters for all other loopback testing.

 LOOP    LINE line-id        COUNT number
                             LENGTH number
                             WITH
                               MIXED
                               ONES
                               ZEROS

  Additional Information (explode) :