SMARTD(8)			  2010-07-12			     SMARTD(8)

NAME
       smartd - SMART Disk Monitoring Daemon

SYNOPSIS
       smartd [options]

FULL PATH
       /usr/sbin/smartd

PACKAGE VERSION
       smartmontools-5.40 2010-07-12 r3124

DESCRIPTION
       smartd  is  a  daemon  that  monitors the Self-Monitoring, Analysis and
       Reporting Technology (SMART) system built into  many  ATA-3  and	 later
       ATA, IDE and SCSI-3 hard drives. The purpose of SMART is to monitor the
       reliability of the hard drive and predict drive failures, and to	 carry
       out  different  types  of  drive self-tests.  This version of smartd is
       compatible with	ATA/ATAPI-7  and  earlier  standards  (see  REFERENCES
       below).

       smartd  will attempt to enable SMART monitoring on ATA devices (equiva‐
       lent to smartctl -s on) and polls these and SCSI devices every 30  min‐
       utes   (configurable),  logging	SMART  errors  and  changes  of	 SMART
       Attributes via the SYSLOG interface.  The default  location  for	 these
       SYSLOG	notifications  and  warnings  is  system-dependent  (typically
       /var/log/messages or /var/log/syslog).  To change  this	default	 loca‐
       tion, please see the ´-l´ command-line option described below.

       In addition to logging to a file, smartd can also be configured to send
       email warnings if problems are detected.	 Depending upon	 the  type  of
       problem,	 you may want to run self-tests on the disk, back up the disk,
       replace the disk, or use a manufacturer´s utility to force reallocation
       of  bad	or  unreadable	disk  sectors.	If disk problems are detected,
       please see the smartctl manual page and the smartmontools web  page/FAQ
       for further guidance.

       If  you send a USR1 signal to smartd it will immediately check the sta‐
       tus of the disks, and then return to polling the disks  every  30  min‐
       utes. See the ´-i´ option below for additional details.

       smartd  can  be	configured  at	start-up  using the configuration file
       /etc/smartd.conf (Windows: EXEDIR/smartd.conf).	If  the	 configuration
       file  is	 subsequently modified, smartd can be told to re-read the con‐
       figuration file by sending it a HUP signal, for example with  the  com‐
       mand:
       killall -HUP smartd.
       (Windows: See NOTES below.)

       On  startup,  if smartd finds a syntax error in the configuration file,
       it will print an error message and then	exit.  However	if  smartd  is
       already running, then is told with a HUP signal to re-read the configu‐
       ration file, and then find a syntax error in this file, it  will	 print
       an  error  message  and	then  continue,	 ignoring  the contents of the
       (faulty) configuration file, as	if  the	 HUP  signal  had  never  been
       received.

       When  smartd  is running in debug mode, the INT signal (normally gener‐
       ated from a shell with CONTROL-C) is treated in the same way as	a  HUP
       signal:	it  makes smartd reload its configuration file. To exit smartd
       use CONTROL-\ (Cygwin: 2x CONTROL-C, Windows: CONTROL-Break).

       On startup, in the absence of the configuration file  /etc/smartd.conf,
       the  smartd daemon first scans for all devices that support SMART.  The
       scanning is done as follows:

       LINUX:	Examine all entries "/dev/hd[a-t]" for	IDE/ATA	 devices,  and
		"/dev/sd[a-z]", "/dev/sd[a-c][a-z]" for SCSI or SATA devices.

       FREEBSD: Authoritative list of disk devices is obtained from SCSI (CAM)
		and ATA subsystems.

       NETBSD/OPENBSD:
		Authoritative list of disk devices  is	obtained  from	sysctl
		´hw.disknames´.

       SOLARIS: Examine	 all entries "/dev/rdsk/c?t?d?s?" for IDE/ATA and SCSI
		disk devices, and entries "/dev/rmt/*" for SCSI tape devices.

       DARWIN:	The IOService plane is scanned for ATA block storage devices.

       WINDOWS 9x/ME:
		Examine	  all	 entries    "/dev/hd[a-d]"    (bitmask	  from
		"\\.\SMARTVSD")	 for  IDE/ATA  devices.	  Examine  all entries
		"/dev/scsi[0-9][0-f]" for SCSI devices on ASPI adapter 0-9, ID
		0-15.

       WINDOWS NT4/2000/XP/2003/Vista:
		Examine	 all entries "/dev/sd[a-j]" ("\\.\PhysicalDrive[0-9]")
		for IDE/(S)ATA and SCSI disk devices

		If a 3ware 9000 controller is installed, examine  all  entries
		"/dev/sdX,N"  for  the first logical drive (´unit´ "/dev/sdX")
		and all physical disks (´ports´	 ",N")	detected  behind  this
		controller. Same for a second controller if present.

       CYGWIN:	See "WINDOWS NT4/2000/XP/2003/Vista" above.

       OS/2,eComStation:
		Use the form "/dev/hd[a-z]" for IDE/ATA devices.

       smartd  then  monitors  for all possible SMART errors (corresponding to
       the ´-a´ Directive in the configuration file;  see  CONFIGURATION  FILE
       below).

OPTIONS
       -A PREFIX, --attributelog=PREFIX
	      [NEW  EXPERIMENTAL  SMARTD  FEATURE]  [ATA  ONLY]	 Writes smartd
	      attribute information (normalized and raw attribute  values)  to
	      files   ´PREFIX´´MODEL-SERIAL.ata.csv´.	At  each  check	 cycle
	      attributes are logged as a line of semicolon separated  triplets
	      of  the  form  "attribute-ID;attribute-norm-value;attribute-raw-
	      value;". Each line is led by a date string of the form "yyyy-mm-
	      dd HH:MM:SS" (in UTC).

	      If  this option is not specified, attribute information is writ‐
	      ten	 to	   files	 ´/var/lib/smartmontools/attr‐
	      log.MODEL-SERIAL.ata.csv´.   To  disable	attribute  log	files,
	      specify this option with an  empty  string  argument:  ´-A  ""´.
	      MODEL  and  SERIAL  are  build  from drive identify information,
	      invalid characters are replaced by underline.

	      If   the	 PREFIX	   has	  the	 form	 ´/path/dir/´	 (e.g.
	      ´/var/lib/smartd/´),  then files ´MODEL-SERIAL.ata.csv´ are cre‐
	      ated in directory ´/path/dir´.   If  the	PREFIX	has  the  form
	      ´/path/name´ (e.g. ´/var/lib/misc/attrlog-´), then files 'nameM‐
	      ODEL-SERIAL.ata.csv' are created	in  directory  '/path/'.   The
	      path must be absolute, except if debug mode is enabled.

       -B [+]FILE, --drivedb=[+]FILE
	      [NEW  EXPERIMENTAL  SMARTD FEATURE] Read the drive database from
	      FILE.  The new  database	replaces  the  built  in  database  by
	      default.	If  ´+´ is specified, then the new entries prepend the
	      built in entries.	 Please see the smartctl(8) man page for  fur‐
	      ther details.

       -c FILE, --configfile=FILE
	      Read  smartd configuration Directives from FILE, instead of from
	      the     default	  location     /etc/smartd.conf	     (Windows:
	      EXEDIR/smartd.conf).   If	 FILE does not exist, then smartd will
	      print an error message and exit with nonzero status.  Thus,  ´-c
	      /etc/smartd.conf´	 can  be  used	to verify the existence of the
	      default configuration file.

	      By using ´-´ for FILE, the configuration is read	from  standard
	      input. This is useful for commands like:
	      echo /dev/hdb -m user@home -M test | smartd -c - -q onecheck
	      to perform quick and simple checks without a configuration file.

       -C, --capabilities
	      Use capabilities(7) (EXPERIMENTAL).

	      Warning: Mail notification does not work when used.

       -d, --debug
	      Runs  smartd  in	"debug" mode. In this mode, it displays status
	      information to STDOUT rather than logging it to SYSLOG and  does
	      not  fork(2) into the background and detach from the controlling
	      terminal.	 In this mode, smartd also prints more verbose	infor‐
	      mation  about  what  it is doing than when operating in "daemon"
	      mode. In this mode, the QUIT signal (normally generated  from  a
	      terminal	with  CONTROL-C) makes smartd reload its configuration
	      file.  Please use CONTROL-\ to exit (Cygwin: 2x CONTROL-C,  Win‐
	      dows: CONTROL-Break).

	      Windows  only:  The  "debug"  mode can be toggled by the command
	      smartd sigusr2. A new console for debug output  is  opened  when
	      debug mode is enabled.

       -D, --showdirectives
	      Prints  a	 list (to STDOUT) of all the possible Directives which
	      may appear in the configuration file /etc/smartd.conf, and  then
	      exits.   These  Directives  are also described later in this man
	      page. They may appear in the configuration  file	following  the
	      device name.

       -h, --help, --usage
	      Prints usage message to STDOUT and exits.

       -i N, --interval=N
	      Sets the interval between disk checks to N seconds, where N is a
	      decimal integer.	The minimum allowed value is ten and the maxi‐
	      mum  is  the largest positive integer that can be represented on
	      your system (often 2^31-1).  The default is 1800 seconds.

	      Note that the superuser can make smartd check the status of  the
	      disks  at any time by sending it the SIGUSR1 signal, for example
	      with the command:
	      kill -SIGUSR1 <pid>
	      where <pid> is the process id number of smartd.	One  may  also
	      use:
	      killall -USR1 smartd
	      for the same purpose.
	      (Windows: See NOTES below.)

       -l FACILITY, --logfacility=FACILITY
	      Uses  syslog  facility FACILITY to log the messages from smartd.
	      Here FACILITY is one of local0, local1, ..., local7,  or	daemon
	      [default].   If  this  command-line  option is not used, then by
	      default messages from smartd are logged to the facility daemon.

	      If you would like to have smartd messages logged somewhere other
	      than  the	 default  location, this can typically be accomplished
	      with (for example) the following steps:

	      [1] Modify the script that starts smartd to include  the	smartd
		  command-line argument ´-l local3´.  This tells smartd to log
		  its messages to facility local3.

	      [2] Modify the syslogd configuration file	 (typically  /etc/sys‐
		  log.conf) by adding a line of the form:
		  local3.* /var/log/smartd.log
		  This	tells  syslogd	to  log all the messages from facility
		  local3 to the designated file: /var/log/smartd.log.

	      [3] Tell syslogd to re-read its configuration file, typically by
		  sending the syslogd process a SIGHUP hang-up signal.

	      [4] Start (or restart) the smartd daemon.

	      For more detailed information, please refer to the man pages for
	      syslog.conf, syslogd, and syslog.	 You may also want  to	modify
	      the  log	rotation  configuration	 files;	 see the man pages for
	      logrotate and examine your system´s /etc/logrotate.conf file.

	      Cygwin: Support for syslogd  as  described  above	 is  available
	      starting	with  Cygwin 1.5.15.  On older releases or if no local
	      syslogd is running, the ´-l´ option  has	no  effect.   In  this
	      case, all syslog messages are written to Windows event log or to
	      file C:/CYGWIN_SYSLOG.TXT if the event log is not available.

	      Windows: Some syslog functionality is implemented internally  in
	      smartd  as follows: If no ´-l´ option (or ´-l daemon´) is speci‐
	      fied, messages are written to  Windows  event  log  or  to  file
	      ./smartd.log  if	event log is not available (Win9x/ME or access
	      denied). By specifying other values of FACILITY, log  output  is
	      redirected  as  follows:	´-l  local0´ to file ./smartd.log, ´-l
	      local1´ to standard output (redirect with ´>´ to any file),  ´-l
	      local2´	to   standard	error,	 ´-l   local[3-7]´:   to  file
	      ./smartd[1-5].log.

	      When using the event log,	 the  enclosed	utility	 syslogevt.exe
	      should  be  registered  as  an event message file to avoid error
	      messages from the event viewer. Use  ´syslogevt  -r  smartd´  to
	      register,	 ´syslogevt  -u	 smartd´ to unregister and ´syslogevt´
	      for more help.

       -n, --no-fork
	      Do not fork into background; this is useful when	executed  from
	      modern init methods like initng, minit or supervise.

	      On  Cygwin, this allows running smartd as service via cygrunsrv,
	      see NOTES below.

	      On Windows,  this	 option	 is  not  available,  use  ´--service´
	      instead.

       -p NAME, --pidfile=NAME
	      Writes  pidfile  NAME  containing	 the  smartd Process ID number
	      (PID).  To avoid symlink attacks	make  sure  the	 directory  to
	      which  pidfile  is  written  is only writable for root.  Without
	      this option, or if the --debug option is given, no PID  file  is
	      written  on startup.  If smartd is killed with a maskable signal
	      then the pidfile is removed.

       -q WHEN, --quit=WHEN
	      Specifies when, if ever, smartd should exit.   The  valid	 argu‐
	      ments are to this option are:

	      nodev  -	Exit  if  there	 are  no devices to monitor, or if any
	      errors are found at startup in the configuration file.  This  is
	      the default.

	      errors  -	 Exit  if  there  are no devices to monitor, or if any
	      errors are found in the configuration file  /etc/smartd.conf  at
	      startup or whenever it is reloaded.

	      nodevstartup  -  Exit  if	 there	are  no	 devices to monitor at
	      startup.	But continue to run if no devices are  found  whenever
	      the configuration file is reloaded.

	      never  -	Only exit if a fatal error occurs (no remaining system
	      memory, invalid command line arguments). In this mode,  even  if
	      there  are  no  devices to monitor, or if the configuration file
	      /etc/smartd.conf has errors, smartd will continue to run,	 wait‐
	      ing to load a configuration file listing valid devices.

	      onecheck	-  Start  smartd in debug mode, then register devices,
	      then check device´s SMART status once, and then exit  with  zero
	      exit status if all of these steps worked correctly.

	      This last option is intended for ´distribution-writers´ who want
	      to create automated scripts to determine whether or not to auto‐
	      matically start up smartd after installing smartmontools.	 After
	      starting smartd with this	 command-line  option,	the  distribu‐
	      tion´s  install  scripts should wait a reasonable length of time
	      (say ten seconds).  If smartd has not exited with zero status by
	      that  time,  the	script should send smartd a SIGTERM or SIGKILL
	      and assume that smartd will not operate correctly on  the	 host.
	      Conversely, if smartd exits with zero status, then it is safe to
	      run smartd in normal daemon mode. If smartd is unable to monitor
	      any  devices  or	encounters  other problems then it will return
	      with non-zero exit status.

	      showtests - Start smartd in debug mode, then  register  devices,
	      then  write a list of future scheduled self tests to stdout, and
	      then exit with zero exit status if all  of  these	 steps	worked
	      correctly.  Device's SMART status is not checked.

	      This  option  is	intended to test whether the '-s REGEX' direc‐
	      tives in smartd.conf will have the desired  effect.  The	output
	      lists  the  next test schedules, limited to 5 tests per type and
	      device. This is followed by a  summary  of  all  tests  of  each
	      device within the next 90 days.

       -r TYPE, --report=TYPE
	      Intended	primarily  to help smartmontools developers understand
	      the behavior of smartmontools on non-conforming  or  poorly-con‐
	      forming  hardware.  This option reports details of smartd trans‐
	      actions with the device.	The option can be used multiple times.
	      When  used  just once, it shows a record of the ioctl() transac‐
	      tions with the device.  When used more than once, the detail  of
	      these  ioctl() transactions are reported in greater detail.  The
	      valid arguments to this option are:

	      ioctl - report all ioctl() transactions.

	      ataioctl - report only ioctl() transactions with ATA devices.

	      scsiioctl - report only ioctl() transactions with SCSI devices.

	      Any argument may include a positive integer to specify the level
	      of  detail that should be reported.  The argument should be fol‐
	      lowed by a comma then the integer with no spaces.	 For  example,
	      ataioctl,2  The  default	level is 1, so ´-r ataioctl,1´ and ´-r
	      ataioctl´ are equivalent.

       -s PREFIX, --savestates=PREFIX
	      [NEW EXPERIMENTAL SMARTD FEATURE] [ATA ONLY] Reads/writes smartd
	      state	   information	      from/to	     files	 ´PRE‐
	      FIX´´MODEL-SERIAL.ata.state´. This preserves  SMART  attributes,
	      drive  min  and max temperatures (-W directive), info about last
	      sent warning email (-m directive), and the time of next check of
	      the self-test REGEXP (-s directive) across boot cycles.

	      If this option is not specified, state information is maintained
	      in files ´/var/lib/smartmontools/smartd.MODEL-SERIAL.ata.state´.
	      To disable state files, specify this option with an empty string
	      argument: ´-s ""´.  MODEL and SERIAL are build from drive	 iden‐
	      tify information, invalid characters are replaced by underline.

	      If    the	   PREFIX    has    the	   form	  ´/path/dir/´	 (e.g.
	      ´/var/lib/smartd/´),  then  files	 ´MODEL-SERIAL.ata.state´  are
	      created  in  directory  ´/path/dir´.  If the PREFIX has the form
	      ´/path/name´ (e.g. ´/var/lib/misc/smartd-´), then files 'nameMO‐
	      DEL-SERIAL.ata.state'  are  created  in directory '/path/'.  The
	      path must be absolute, except if debug mode is enabled.

	      The state information files are  read  on	 smartd	 startup.  The
	      files  are  always  (re)written  after reading the configuration
	      file, before rereading the configuration file  (SIGHUP),	before
	      smartd  shutdown,	 and  after a check forced by SIGUSR1. After a
	      normal check cycle, a file is only  rewritten  if	 an  important
	      change (which usually results in a SYSLOG output) occurred.

       --service
	      Cygwin and Windows only: Enables smartd to run as a Windows ser‐
	      vice.

	      On Cygwin, this option is kept for backward compatibility	 only.
	      It has the same effect as ´-n, --no-fork´, see above.

	      On  Windows,  this  option  enables the buildin service support.
	      The option must be specified in the service command line as  the
	      first  argument.	It should not be used from console.  See NOTES
	      below for details.

       -V, --version, --license, --copyright
	      Prints version, copyright, license, home page and	 SVN  revision
	      information  for	your  copy of smartd to STDOUT and then exits.
	      Please include this information if you  are  reporting  bugs  or
	      problems.

EXAMPLES
       smartd
       Runs  the  daemon in forked mode. This is the normal way to run smartd.
       Entries are logged to SYSLOG.

       smartd -d -i 30
       Run in foreground (debug) mode, checking the disk status every 30  sec‐
       onds.

       smartd -q onecheck
       Registers  devices,  and checks the status of the devices exactly once.
       The exit status (the bash $?  variable) will be zero if all went	 well,
       and  nonzero  if	 no  devices  were  detected or some other problem was
       encountered.

       Note   that   smartmontools   provides	 a    start-up	  script    in
       /etc/init.d/smartd  which  is responsible for starting and stopping the
       daemon via the normal init interface.  Using this script, you can start
       smartd by giving the command:
       /etc/init.d/smartd start
       and stop it by using the command:
       /etc/init.d/smartd stop

CONFIGURATION FILE /etc/smartd.conf
       In  the absence of a configuration file, under Linux smartd will try to
       open the 20 ATA devices /dev/hd[a-t] and the 26 SCSI devices /dev/sd[a-
       z].   Under  FreeBSD,  smartd will try to open all existing ATA devices
       (with entries in /dev) /dev/ad[0-9]+  and  all  existing	 SCSI  devices
       (using  CAM  subsystem).	 Under NetBSD/OpenBSD, smartd will try to open
       all existing ATA devices (with entries in /dev) /dev/wd[0-9]+c and  all
       existing SCSI devices /dev/sd[0-9]+c.  Under Solaris smartd will try to
       open  all  entries  "/dev/rdsk/c?t?d?s?"	 for  IDE/ATA  and  SCSI  disk
       devices, and entries "/dev/rmt/*" for SCSI tape devices.	 Under Windows
       smartd  will  try  to  open  all	 entries  "/dev/hd[a-j]"  ("\\.\Physi‐
       calDrive[0-9]")	for  IDE/ATA devices on WinNT4/2000/XP, "/dev/hd[a-d]"
       (bitmask from "\\.\SMARTVSD") for IDE/ATA devices on  Win95/98/98SE/ME,
       and  "/dev/scsi[0-9][0-7]"  (ASPI adapter 0-9, ID 0-7) for SCSI devices
       on all versions of Windows.  Under Darwin, smartd  will	open  any  ATA
       block storage device.

       This  can  be  annoying if you have an ATA or SCSI device that hangs or
       misbehaves when receiving SMART commands.  Even if this causes no prob‐
       lems,  you  may	be  annoyed  by the string of error log messages about
       block-major devices that can´t be found, and SCSI devices that can´t be
       opened.

       One  can	 avoid	this  problem, and gain more control over the types of
       events  monitored  by  smartd,  by   using   the	  configuration	  file
       /etc/smartd.conf.   This	 file  contains	 a list of devices to monitor,
       with one device per line.  An example file is included with the	smart‐
       montools	 distribution. You will find this sample configuration file in
       /usr/share/doc/smartmontools/. For  security,  the  configuration  file
       should not be writable by anyone but root. The syntax of the file is as
       follows:

       ·   There should be one device listed per line, although you  may  have
	   lines that are entirely comments or white space.

       ·   Any text following a hash sign ´#´ and up to the end of the line is
	   taken to be a comment, and ignored.

       ·   Lines may be continued by using a backslash ´\´ as  the  last  non-
	   whitespace or non-comment item on a line.

       ·   Note: a line whose first character is a hash sign ´#´ is treated as
	   a white-space blank line, not as a non-existent line, and will  end
	   a continuation line.

       Here  is an example configuration file.	It´s for illustrative purposes
       only; please don´t copy it onto your system without reading to the  end
       of the DIRECTIVES Section below!

       ################################################
       # This is an example smartd startup config file
       # /etc/smartd.conf for monitoring three
       # ATA disks, three SCSI disks, six ATA disks
       # behind two 3ware controllers, two disks on a cciss
       # controller, three SATA disks directly connected
       # to the HighPoint Rocket-RAID controller,
       # two SATA disks connected to the HighPoint
       # RocketRAID controller via a pmport
       # device, four SATA disks connected to an Areca
       # RAID controller, and one SATA disk.
       #
       # First ATA disk on two different interfaces. On
       # the second disk, start a long self-test every
       # Sunday between 3 and 4 am.
       #
	 /dev/hda -a -m admin@example.com,root@localhost
	 /dev/hdc -a -I 194 -I 5 -i 12 -s L/../../7/03
       #
       # SCSI disks. Send a TEST warning email to admin on
       # startup.
       #
	 /dev/sda
	 /dev/sdb -m admin@example.com -M test
       #
       # Strange device. It´s SCSI. Start a scheduled
       # long self test between 5 and 6 am Monday/Thursday
	 /dev/weird -d scsi -s L/../../(1|4)/05
       #
       # An ATA disk may appear as a SCSI device to the
       # OS. If a SCSI to ATA Translation (SAT) layer
       # is between the OS and the device then this can be
       # flagged with the '-d sat' option. This situation
       # may become common with SATA disks in SAS and FC
       # environments.
	 /dev/sda -a -d sat
       #
       # Three disks connected to a MegaRAID controller
       # Start short self-tests daily between 1-2, 2-3, and
       # 3-4 am.
	 /dev/sda -d megaraid,0 -a -s S/../.././01
	 /dev/sda -d megaraid,1 -a -s S/../.././02
	 /dev/sda -d megaraid,2 -a -s S/../.././03
       #
       # Four ATA disks on a 3ware 6/7/8000 controller.
       # Start short self-tests daily between midnight and 1am,
       # 1-2, 2-3, and 3-4 am. Starting with the Linux 2.6
       # kernel series, /dev/sdX is deprecated in favor of
       # /dev/tweN. For example replace /dev/sdc by /dev/twe0
       # and /dev/sdd by /dev/twe1.
	 /dev/sdc -d 3ware,0 -a -s S/../.././00
	 /dev/sdc -d 3ware,1 -a -s S/../.././01
	 /dev/sdd -d 3ware,2 -a -s S/../.././02
	 /dev/sdd -d 3ware,3 -a -s S/../.././03
       #
       # Two ATA disks on a 3ware 9000 controller.
       # Start long self-tests Sundays between midnight and
       # 1am and 2-3 am
	 /dev/twa0 -d 3ware,0 -a -s L/../../7/00
	 /dev/twa0 -d 3ware,1 -a -s L/../../7/02
       #
       # Two SATA (not SAS) disks on a 3ware 9750 controller.
       # Start long self-tests Sundays between midnight and
       # 1am and 2-3 am
	 /dev/twl0 -d 3ware,0 -a -s L/../../7/00
	 /dev/twl0 -d 3ware,1 -a -s L/../../7/02
       #
       # Monitor 2 disks connected to the first HP SmartArray controller which
       # uses the cciss driver. Start long tests on Sunday nights and short
       # self-tests every night and send errors to root
	 /dev/cciss/c0d0 -d cciss,0 -a -s (L/../../7/02|S/../.././02) -m root
	 /dev/cciss/c0d0 -d cciss,1 -a -s (L/../../7/03|S/../.././03) -m root
       #
       # Three SATA disks on a HighPoint RocketRAID controller.
       # Start short self-tests daily between 1-2, 2-3, and
       # 3-4 am.
       # under Linux
	 /dev/sde -d hpt,1/1 -a -s S/../.././01
	 /dev/sde -d hpt,1/2 -a -s S/../.././02
	 /dev/sde -d hpt,1/3 -a -s S/../.././03
       # or under FreeBSD
       # /dev/hptrr -d hpt,1/1 -a -s S/../.././01
       # /dev/hptrr -d hpt,1/2 -a -s S/../.././02
       # /dev/hptrr -d hpt,1/3 -a -s S/../.././03
       #
       # Two SATA disks connected to a HighPoint RocketRAID
       # via a pmport device. Start long self-tests Sundays
       # between midnight and 1am and 2-3 am.
       # under Linux
	 /dev/sde -d hpt,1/4/1 -a -s L/../../7/00
	 /dev/sde -d hpt,1/4/2 -a -s L/../../7/02
       # or under FreeBSD
       # /dev/hptrr -d hpt,1/4/1 -a -s L/../../7/00
       # /dev/hptrr -d hpt,1/4/2 -a -s L/../../7/02
       #
       # Three SATA disks connected to an Areca
       # RAID controller. Start long self-tests Sundays
       # between midnight and 3 am.
	 /dev/sg2 -d areca,1 -a -s L/../../7/00
	 /dev/sg2 -d areca,2 -a -s L/../../7/01
	 /dev/sg2 -d areca,3 -a -s L/../../7/02
       #
       # The following line enables monitoring of the
       # ATA Error Log and the Self-Test Error Log.
       # It also tracks changes in both Prefailure
       # and Usage Attributes, apart from Attributes
       # 9, 194, and 231, and shows continued lines:
       #
	 /dev/hdd -l error \
		  -l selftest \
		  -t \	    # Attributes not tracked:
		  -I 194 \  # temperature
		  -I 231 \  # also temperature
		  -I 9	    # power-on hours
       #
       ################################################

CONFIGURATION FILE DIRECTIVES
       If  a  non-comment  entry  in the configuration file is the text string
       DEVICESCAN in capital letters, then smartd will	ignore	any  remaining
       lines in the configuration file, and will scan for devices.  DEVICESCAN
       may optionally be followed by Directives that will apply to all devices
       that are found in the scan.  Please see below for additional details.

       The  following  are the Directives that may appear following the device
       name or DEVICESCAN on any line of  the  /etc/smartd.conf	 configuration
       file.  Note  that  these	 are NOT command-line options for smartd.  The
       Directives below may appear in any order, following the device name.

       For an ATA device, if no Directives appear, then	 the  device  will  be
       monitored  as  if the ´-a´ Directive (monitor all SMART properties) had
       been given.

       If a SCSI disk is listed, it will be monitored at  the  maximum	imple‐
       mented  level: roughly equivalent to using the ´-H -l selftest´ options
       for an ATA disk.	 So with the exception of ´-d´, ´-m´,  ´-l  selftest´,
       ´-s´,  and  ´-M´, the Directives below are ignored for SCSI disks.  For
       SCSI disks, the ´-m´ Directive sends a warning email if the SMART  sta‐
       tus indicates a disk failure or problem, if the SCSI inquiry about disk
       status fails, or if new errors appear in the self-test log.

       If a 3ware controller is used then the corresponding SCSI (/dev/sd?) or
       character  device  (/dev/twe?,  /dev/twa? or /dev/twl?) must be listed,
       along with the ´-d 3ware,N´ Directive (see below).  The individual  ATA
       disks  hosted  by  the  3ware controller appear to smartd as normal ATA
       devices.	 Hence all the ATA directives can be used for these disks (but
       see note below).

       If  an  Areca  controller  is  used then the corresponding SCSI generic
       device (/dev/sg?)  must be listed, along with the ´-d  areca,N´	Direc‐
       tive  (see  below).  The individual SATA disks hosted by the Areca con‐
       troller appear to smartd as normal ATA  devices.	  Hence	 all  the  ATA
       directives can be used for these disks.	Areca firmware version 1.46 or
       later which  supports  smartmontools  must  be  used;  Please  see  the
       smartctl(8) man page for further details.

       -d TYPE
	      Specifies	 the  type  of the device.  This Directive may be used
	      multiple times for one device, but the arguments ata, scsi, sat,
	      marvell,	cciss,N, areca,N, megaraid,N and 3ware,N are mutually-
	      exclusive. If more than one is given then smartd	will  use  the
	      last one which appears.

	      If  none	of  these  three  arguments is given, then smartd will
	      first attempt to guess the device type by looking at whether the
	      sixth  character	in  the device name is an ´s´ or an ´h´.  This
	      will work for device names like /dev/hda or /dev/sdb, and corre‐
	      sponds  to  choosing  ata	 or scsi respectively. If smartd can´t
	      guess from this sixth character, then  it	 will  simply  try  to
	      access the device using first ATA and then SCSI ioctl()s.

	      The valid arguments to this Directive are:

	      ata - the device type is ATA.  This prevents smartd from issuing
	      SCSI commands to an ATA device.

	      scsi - the device type is SCSI.  This prevents smartd from issu‐
	      ing ATA commands to a SCSI device.

	      sat  - the device type is SCSI to ATA Translation (SAT).	smartd
	      will generate ATA (smart) commands and then package them in  the
	      SAT  defined  ATA	 PASS  THROUGH SCSI commands. The commands are
	      then routed through the SCSI pass through interface to the oper‐
	      ating  system. There are two types of ATA PASS THROUGH SCSI com‐
	      mands: a 12 byte and 16 byte variant.  smartd can use either and
	      defaults	to  the	 16  byte variant. This can be overridden with
	      this syntax: ´-d sat,12´ or ´-d sat,16´.

	      marvell - Under Linux, interact with SATA disks  behind  Marvell
	      chip-set	controllers  (using  the  Marvell  rather  than libata
	      driver).

	      megaraid,N - the device consists of one  or  more	 SCSI/SAS/SATA
	      disks  connected	to  a  MegaRAID	 controller.  The non-negative
	      integer N (in the range of 0 to  127  inclusive)	denotes	 which
	      disk  on	the  controller	 is monitored.	In log files and email
	      messages this disk will be identified as megaraid_disk_XXX  with
	      XXX in the range from 000 to 127 inclusive.

	      3ware,N - the device consists of one or more ATA disks connected
	      to a 3ware RAID controller. The non-negative integer N  (in  the
	      range  from  0  to 127 inclusive) denotes which disk on the con‐
	      troller is monitored.  In log files and email messages this disk
	      will  be identified as 3ware_disk_XXX with XXX in the range from
	      000 to 127 inclusive.

	      This Directive may at first appear confusing, because the	 3ware
	      controller  is  a	 SCSI  device (such as /dev/sda) and should be
	      listed as such in the the configuration file.  However when  the
	      ´-d  3ware,N´  Directive is used, then the corresponding disk is
	      addressed using native ATA commands which are  ´passed  through´
	      the  SCSI driver. All ATA Directives listed in this man page may
	      be used.	Note that while you may use any of the 3ware SCSI log‐
	      ical  devices  /dev/sd?  to  address  any	 of the physical disks
	      (3ware ports), error and log messages will make the  most	 sense
	      if  you  always list the 3ware SCSI logical device corresponding
	      to the particular physical disks.	 Please	 see  the  smartctl(8)
	      man page for further details.

	      ATA disks behind 3ware controllers may alternatively be accessed
	      via   a	character   device   interface	 /dev/twe0-15	(3ware
	      6000/7000/8000  controllers),  /dev/twa0-15  (3ware  9000 series
	      controllers) and /dev/twl0-15 (3ware 9750	 series	 controllers).
	      Note that the 9000 series controllers may only be accessed using
	      the character device interface /dev/twa0-15  and	not  the  SCSI
	      device  interface /dev/sd?.  Please see the smartctl(8) man page
	      for further details.

	      Note  that  older	 3w-xxxx  drivers  do  not  pass  the  ´Enable
	      Autosave´	 (-S  on)  and ´Enable Automatic Offline´ (-o on) com‐
	      mands to the disk, if the SCSI interface is  used,  and  produce
	      these types of harmless syslog error messages instead: ´3w-xxxx:
	      tw_ioctl(): Passthru size (123392) too big´. This can  be	 fixed
	      by  upgrading  to	 version  1.02.00.037  or later of the 3w-xxxx
	      driver,  or  by  applying	 a  patch  to  older  versions.	   See
	      http://smartmontools.sourceforge.net/  for instructions.	Alter‐
	      natively use the character device interfaces /dev/twe0-15 (3ware
	      6/7/8000	series	controllers),  /dev/twa0-15 (3ware 9000 series
	      controllers) or /dev/twl0-15 (3ware 9750 series controllers).

	      areca,N - the device consists of one or  more  SATA  disks  con‐
	      nected to an Areca SATA RAID controller.	The positive integer N
	      (in the range from 1 to 24 inclusive) denotes which disk on  the
	      controller  is  monitored.  In log files and email messages this
	      disk will be identifed as areca_disk_XX with  XX	in  the	 range
	      from 01 to 24 inclusive.

	      cciss,N  -  the  device  consists of one or more SCSI disks con‐
	      nected to a cciss RAID controller. The  non-negative  integer  N
	      (in  the range from 0 to 15 inclusive) denotes which disk on the
	      controller is monitored.	In log files and email	messages  this
	      disk  will  be  identified as cciss_disk_XX with XX in the range
	      from 00 to 15 inclusive.

	      3ware, MegaRAID, Areca and cciss controllers are currently  ONLY
	      supported under Linux.

	      hpt,L/M/N	 -  the	 device consists of one or more ATA disks con‐
	      nected to a HighPoint RocketRAID controller.  The integer	 L  is
	      the  controller id, the integer M is the channel number, and the
	      integer N is the PMPort number if it is available.  The  allowed
	      values  of L are from 1 to 4 inclusive, M are from 1 to 8 inclu‐
	      sive and N from 1 to 4 if PMPort available.  And also these val‐
	      ues  are	limited	 by the model of the HighPoint RocketRAID con‐
	      troller.	In log files and email	messages  this	disk  will  be
	      identified  as hpt_X/X/X and X/X/X is the same as L/M/N, note if
	      no N indicated, N set to the default value 1.

	      HighPoint RocketRAID controllers are  currently  ONLY  supported
	      under Linux and FreeBSD.

	      removable	 -  the	 device or its media is removable.  This indi‐
	      cates to smartd that it should  continue	(instead  of  exiting,
	      which  is the default behavior) if the device does not appear to
	      be present when smartd is started.  This Directive may  be  used
	      in conjunction with the other ´-d´ Directives.

       -n POWERMODE[,N][,q]
	      This  ´nocheck´  Directive  is used to prevent a disk from being
	      spun-up when it is periodically polled by smartd.

	      ATA disks have five different power states. In order of increas‐
	      ing  power  consumption  they  are:  ´OFF´,  ´SLEEP´, ´STANDBY´,
	      ´IDLE´, and ´ACTIVE´.  Typically in the OFF, SLEEP, and  STANDBY
	      modes  the  disk´s  platters  are	 not spinning. But usually, in
	      response to SMART commands issued by smartd, the	disk  platters
	      are  spun	 up.  So if this option is not used, then a disk which
	      is  in  a	 low-power  mode  may  be  spun	 up  and  put  into  a
	      higher-power mode when it is periodically polled by smartd.

	      Note  that  if the disk is in SLEEP mode when smartd is started,
	      then it won't respond to smartd commands, and so the disk	 won't
	      be registered as a device for smartd to monitor. If a disk is in
	      any other low-power mode, then the commands issued by smartd  to
	      register the disk will probably cause it to spin-up.

	      The  ´-n´	 (nocheck)  Directive  specifies  if smartd´s periodic
	      checks should still be carried out  when	the  device  is	 in  a
	      low-power	 mode.	 It  may  be used to prevent a disk from being
	      spun-up by periodic smartd polling.  The allowed values of  POW‐
	      ERMODE are:

	      never  -	smartd	will poll (check) the device regardless of its
	      power mode. This may cause a  disk  which	 is  spun-down	to  be
	      spun-up  when smartd checks it.  This is the default behavior if
	      the '-n' Directive is not given.

	      sleep - check the device unless it is in SLEEP mode.

	      standby - check the device unless it  is	in  SLEEP  or  STANDBY
	      mode.   In  these	 modes	most disks are not spinning, so if you
	      want to prevent a laptop disk from spinning up  each  time  that
	      smartd polls, this is probably what you want.

	      idle  -  check the device unless it is in SLEEP, STANDBY or IDLE
	      mode.  In the IDLE state, most disks are still spinning, so this
	      is probably not what you want.

	      Maximum  number of skipped checks (in a row) can be specified by
	      appending	 positive  number  ´,N´	  to   POWERMODE   (like   ´-n
	      standby,15´).  After N checks are skipped in a row, powermode is
	      ignored and the check is performed anyway.

	      When a periodic test  is	skipped,  smartd  normally  writes  an
	      informal log message. The message can be suppressed by appending
	      the option ´,q´ to POWERMODE (like ´-n standby,q´).   This  pre‐
	      vents a laptop disk from spinning up due to this message.

	      Both ´,N´ and ´,q´ can be specified together.

       -T TYPE
	      Specifies	 how  tolerant smartd should be of SMART command fail‐
	      ures.  The valid arguments to this Directive are:

	      normal - do not try to monitor the disk  if  a  mandatory	 SMART
	      command  fails, but continue if an optional SMART command fails.
	      This is the default.

	      permissive - try to monitor the disk even if it appears to  lack
	      SMART  capabilities.   This  may	be required for some old disks
	      (prior to ATA-3 revision 4) that implemented  SMART  before  the
	      SMART  standards were incorporated into the ATA/ATAPI Specifica‐
	      tions.  This may also be needed for some Maxtor disks which fail
	      to  comply  with the ATA Specifications and don't properly indi‐
	      cate support for error- or self-test logging.

	      [Please see the smartctl -T command-line option.]

       -o VALUE
	      Enables or disables SMART Automatic Offline Testing when	smartd
	      starts  up  and  has  no further effect.	The valid arguments to
	      this Directive are on and off.

	      The delay between tests is  vendor-specific,  but	 is  typically
	      four hours.

	      Note that SMART Automatic Offline Testing is not part of the ATA
	      Specification.  Please see the smartctl -o  command-line	option
	      documentation for further information about this feature.

       -S VALUE
	      Enables or disables Attribute Autosave when smartd starts up and
	      has no further effect.  The valid arguments  to  this  Directive
	      are  on  and  off.   Also affects SCSI devices.  [Please see the
	      smartctl -S command-line option.]

       -H     Check the SMART health status of the disk.   If  any  Prefailure
	      Attributes  are  less  than  or equal to their threshold values,
	      then disk failure is predicted in less than 24 hours, and a mes‐
	      sage  at	loglevel ´LOG_CRIT´ will be logged to syslog.  [Please
	      see the smartctl -H command-line option.]

       -l TYPE
	      Reports increases in the number of errors in one of three	 SMART
	      logs.  The valid arguments to this Directive are:

	      error  - report if the number of ATA errors reported in the Sum‐
	      mary SMART error log has increased since the last check.

	      xerror - [NEW EXPERIMENTAL SMARTD FEATURE] report if the	number
	      of ATA errors reported in the Extended Comprehensive SMART error
	      log has increased since the last check.

	      If both ´-l error´ and ´-l xerror´ are specified, smartd	checks
	      the maximum of both values.

	      [Please see the smartctl -l xerror command-line option.]

	      selftest	- report if the number of failed tests reported in the
	      SMART Self-Test Log has increased since the last	check,	or  if
	      the  timestamp  associated  with the most recent failed test has
	      increased.  Note that such errors will only be logged if you run
	      self-tests  on  the disk (and it fails a test!).	Self-Tests can
	      be run automatically by smartd: please see  the  ´-s´  Directive
	      below.   Self-Tests  can	also  be  run  manually	 by  using the
	      ´-t short´ and ´-t long´ options of smartctl and the results  of
	      the  testing  can	 be  observed using the smartctl ´-l selftest´
	      command-line option.]

	      [Please see the smartctl -l and -t command-line options.]

       -s REGEXP
	      Run Self-Tests or Offline Immediate Tests, at  scheduled	times.
	      A	 Self-	or  Offline  Immediate	Test will be run at the end of
	      periodic device polling, if all  12  characters  of  the	string
	      T/MM/DD/d/HH match the extended regular expression REGEXP. Here:

	      T	  is the type of the test.  The values that smartd will try to
		  match (in turn) are: ´L´ for a Long  Self-Test,  ´S´	for  a
		  Short	 Self-Test, ´C´ for a Conveyance Self-Test (ATA only),
		  and ´O´ for an Offline Immediate Test (ATA only).   As  soon
		  as  a	 match is found, the test will be started and no addi‐
		  tional matches will be  sought  for  that  device  and  that
		  polling cycle.

		  [NEW EXPERIMENTAL SMARTD FEATURE] To run scheduled Selective
		  Self-Tests, use ´n´ for next span, ´r´ to redo last span, or
		  ´c´  to  continue  with next span or redo last span based on
		  status of last test. The LBA range is	 based	on  the	 first
		  span	 from	the   last   test.    See   the	  smartctl  -t
		  select,[next|redo|cont] options for further info.

	      MM  is the month of the year, expressed with two decimal digits.
		  The  range  is from 01 (January) to 12 (December) inclusive.
		  Do not use a single decimal digit or the match  will	always
		  fail!

	      DD  is  the day of the month, expressed with two decimal digits.
		  The range is from 01 to 31 inclusive.	 Do not use  a	single
		  decimal digit or the match will always fail!

	      d	  is  the  day	of the week, expressed with one decimal digit.
		  The range is from 1 (Monday) to 7 (Sunday) inclusive.

	      HH  is the hour of the day, written with two decimal digits, and
		  given in hours after midnight.  The range is 00 (midnight to
		  just before 1am) to 23 (11pm to just before midnight) inclu‐
		  sive.	  Do  not use a single decimal digit or the match will
		  always fail!

	      Some examples follow.  In reading these, keep in	mind  that  in
	      extended	regular expressions a dot ´.´ matches any single char‐
	      acter, and a parenthetical expression such as ´(A|B|C)´  denotes
	      any one of the three possibilities A, B, or C.

	      To schedule a short Self-Test between 2-3am every morning, use:
	       -s S/../.././02
	      To schedule a long Self-Test between 4-5am every Sunday morning,
	      use:
	       -s L/../../7/04
	      To schedule a long Self-Test between 10-11pm on  the  first  and
	      fifteenth day of each month, use:
	       -s L/../(01|15)/./22
	      To schedule an Offline Immediate test after every midnight, 6am,
	      noon,and 6pm, plus a Short Self-Test daily at 1-2am and  a  Long
	      Self-Test every Saturday at 3-4am, use:
	       -s (O/../.././(00|06|12|18)|S/../.././01|L/../../6/03)
	      If  Long Self-Tests of a large disks take longer than the system
	      uptime, a full disk test can be performed by  several  Selective
	      Self-Tests.   To	setup a full test of a 1TB disk within 20 days
	      (one 50GB span each day), run this command once:
		smartctl -t select,0-99999999 /dev/sda
	      To run the next test spans on Monday-Friday between 12-13am, run
	      smartd with this directive:
	       -s n/../../[1-5]/12

	      Scheduled	 tests	are  run  immediately following the regularly-
	      scheduled device polling, if the current local date,  time,  and
	      test  type,  match  REGEXP.   By default the regularly-scheduled
	      device  polling  occurs  every  thirty  minutes  after  starting
	      smartd.	Take  caution  if you use the ´-i´ option to make this
	      polling interval more than sixty minutes:	 the  poll  times  may
	      fail  to	coincide  with	any of the testing times that you have
	      specified with REGEXP.  In this case the test will be  run  fol‐
	      lowing the next device polling.

	      Before running an offline or self-test, smartd checks to be sure
	      that a self-test is not already  running.	  If  a	 self-test  is
	      already  running, then this running self test will not be inter‐
	      rupted to begin another test.

	      smartd will not attempt to run any type of test if another  test
	      was already started or run in the same hour.

	      To  avoid	 performance  problems during system boot, smartd will
	      not attempt to run any scheduled tests following the very	 first
	      device polling (unless ´-q onecheck´ is specified).

	      Each  time  a  test  is run, smartd will log an entry to SYSLOG.
	      You can use these or the '-q showtests' command-line  option  to
	      verify  that  you	 constructed  REGEXP  correctly.  The matching
	      order (L before S before C before O) ensures  that  if  multiple
	      test  types are all scheduled for the same hour, the longer test
	      type has precedence.  This is usually the desired behavior.

	      If the scheduled tests are used in conjunction with  state  per‐
	      sistence	(´-s´ option), smartd will also try to match the hours
	      since last shutdown (or 90 days at most). If any test would have
	      been  started  during downtime, the longest (see above) of these
	      tests is run after second device polling.

	      If the ´-n´ directive is used  and  any  test  would  have  been
	      started  during disk standby time, the longest of these tests is
	      run when the disk is active again.

	      Unix users: please beware that the rules	for  extended  regular
	      expressions  [regex(7)]  are  not	 the  same  as	the  rules for
	      file-name pattern matching by the shell [glob(7)].  smartd  will
	      issue  harmless  informational  warning  messages	 if it detects
	      characters in REGEXP that appear to indicate that you have  made
	      this mistake.

       -m ADD Send a warning email to the email address ADD if the ´-H´, ´-l´,
	      ´-f´, ´-C´, or ´-O´ Directives detect a failure or a new	error,
	      or  if  a	 SMART	command to the disk fails. This Directive only
	      works in conjunction with these other Directives	(or  with  the
	      equivalent default ´-a´ Directive).

	      To prevent your email in-box from getting filled up with warning
	      messages, by default only a single warning will be sent for each
	      of the enabled alert types, ´-H´, ´-l´, ´-f´, ´-C´, or ´-O´ even
	      if more than one failure or error is detected or if the  failure
	      or error persists.  [This behavior can be modified; see the ´-M´
	      Directive below.]

	      To send email to more than one user, please  use	the  following
	      "comma	  separated"	  form	    for	     the      address:
	      user1@add1,user2@add2,...,userN@addN (with no spaces).

	      To test that email is being sent correctly, use  the  ´-M	 test´
	      Directive	 described  below  to  send  one test email message on
	      smartd startup.

	      By default, email is sent using the  system  mail	 command.   In
	      order  that smartd find the mail command (normally /bin/mail) an
	      executable named ´mail´ must be in the  path  of	the  shell  or
	      environment from which smartd was started.  If you wish to spec‐
	      ify an  explicit	path  to  the  mail  executable	 (for  example
	      /usr/local/bin/mail)  or	a custom script to run, please use the
	      ´-M exec´ Directive below.

	      Note that by default under Solaris, in the  previous  paragraph,
	      ´mailx´  and  ´/bin/mailx´  are  used, since Solaris ´/bin/mail´
	      does not accept a ´-s´ (Subject) command-line argument.

	      On Windows, the ´Blat´ mailer (http://blat.sourceforge.net/)  is
	      used by default.	This mailer uses a different command line syn‐
	      tax, see ´-M exec´ below.

	      Note also that there is a special argument <nomailer> which  can
	      be given to the ´-m´ Directive in conjunction with the ´-M exec´
	      Directive. Please see below for an explanation of its effect.

	      If the mailer or the shell running it produces any STDERR/STDOUT
	      output,  then a snippet of that output will be copied to SYSLOG.
	      The remainder of	the  output  is	 discarded.  If	 problems  are
	      encountered  in sending mail, this should help you to understand
	      and fix them.  If you have mail problems, we  recommend  running
	      smartd  in  debug	 mode  with the ´-d´ flag, using the ´-M test´
	      Directive described below.

	      The following extension is available on Windows:	By  specifying
	      ´msgbox´	as a mail address, a warning "email" is displayed as a
	      message box on the screen.  Using both ´msgbox´ and regular mail
	      addresses	 is  possible,	if  ´msgbox´  is the first word in the
	      comma separated list.  With ´sysmsgbox´, a system modal  (always
	      on  top) message box is used. If running as a service, a service
	      notification message box (always shown on current visible	 desk‐
	      top) is used.

       -M TYPE
	      These  Directives	 modify the behavior of the smartd email warn‐
	      ings enabled with the  ´-m´  email  Directive  described	above.
	      These  ´-M´  Directives  only  work in conjunction with the ´-m´
	      Directive and can not be used without it.

	      Multiple -M Directives may be given.  If more than  one  of  the
	      following	 three	-M  Directives	are given (example: -M once -M
	      daily) then the final one (in the example, -M daily) is used.

	      The valid arguments to the -M Directive are (one of the  follow‐
	      ing three):

	      once - send only one warning email for each type of disk problem
	      detected.	 This is the default.

	      daily - send additional warning reminder emails, once  per  day,
	      for each type of disk problem detected.

	      diminishing  -  send additional warning reminder emails, after a
	      one-day interval, then  a	 two-day  interval,  then  a  four-day
	      interval, and so on for each type of disk problem detected. Each
	      interval is twice as long as the previous interval.

	      In addition, one may add zero or more of	the  following	Direc‐
	      tives:

	      test - send a single test email immediately upon smartd startup.
	      This allows one to verify that  email  is	 delivered  correctly.
	      Note  that  if this Directive is used, smartd will also send the
	      normal email warnings that were enabled with the ´-m´ Directive,
	      in addition to the single test email!

	      exec  PATH - run the executable PATH instead of the default mail
	      command, when smartd needs to send email.	 PATH must point to an
	      executable binary file or script.

	      By  setting  PATH	 to point to a customized script, you can make
	      smartd perform useful tricks when a  disk	 problem  is  detected
	      (beeping	the  console,  shutting down the machine, broadcasting
	      warnings to all logged-in users, etc.)  But please  be  careful.
	      smartd  will block until the executable PATH returns, so if your
	      executable hangs,	 then  smartd  will  also  hang.  Some	sample
	      scripts  are  included  in /usr/share/doc/smartmontools/example‐
	      scripts/.

	      The return status of the executable is  recorded	by  smartd  in
	      SYSLOG.  The  executable	is  not expected to write to STDOUT or
	      STDERR.  If it does, then this is interpreted as indicating that
	      something is going wrong with your executable, and a fragment of
	      this output is logged to SYSLOG to help you  to  understand  the
	      problem.	Normally, if you wish to leave some record behind, the
	      executable should send mail or write to a file or device.

	      Before running the executable, smartd sets a number of  environ‐
	      ment variables.  These environment variables may be used to con‐
	      trol  the	 executable´s  behavior.   The	environment  variables
	      exported by smartd are:

	      SMARTD_MAILER
		  is  set  to  the  argument of -M exec, if present or else to
		  ´mail´ (examples: /bin/mail, mail).

	      SMARTD_DEVICE
		  is set to the device path (examples: /dev/hda, /dev/sdb).

	      SMARTD_DEVICETYPE
		  is set to the	 device	 type  (possible  values:  ata,	 scsi,
		  3ware,  cciss,  N,  areca,N,	hpt,L/M/N).   Here N=0,...,127
		  denotes the ATA disk behind a 3ware or cciss RAID controller
		  and  L/M/N  denotes  the SATA disk behind a HighPoint Rocke‐
		  tRAID controller.

	      SMARTD_DEVICESTRING
		  is set to the device description.  For SMARTD_DEVICETYPE  of
		  ata  or  scsi, this is the same as SMARTD_DEVICE.  For 3ware
		  RAID	 controllers,	the    form    used    is    ´/dev/sdc
		  [3ware_disk_01]´.   For HighPoint RocketRAID controller, the
		  form is ´/dev/sdd [hpt_1/1/1]´ under	Linux  or  ´/dev/hptrr
		  [hpt_1/1/1]´ under FreeBSD.  For Areca controllers, the form
		  is ´/dev/sg2 [areca_disk_09]´.  In these  cases  the	device
		  string  contains  a  space  and  is  NOT  quoted.  So to use
		  $SMARTD_DEVICESTRING in a bash script	 you  should  probably
		  enclose it in double quotes.

	      SMARTD_FAILTYPE
		  gives the reason for the warning or message email.  The pos‐
		  sible values that it takes and their meanings are:
		  EmailTest: this is an email test message.
		  Health: the SMART health status indicates imminent failure.
		  Usage: a usage Attribute has failed.
		  SelfTest: the number of self-test failures has increased.
		  ErrorCount: the number of errors in the ATA  error  log  has
		  increased.
		  CurrentPendingSector:	 one of more disk sectors could not be
		  read and are marked to be reallocated (replaced  with	 spare
		  sectors).
		  OfflineUncorrectableSector:	during	off-line  testing,  or
		  self-testing, one or more disk sectors could not be read.
		  Temperature: Temperature  reached  critical  limit  (see  -W
		  directive).
		  FailedHealthCheck: the SMART health status command failed.
		  FailedReadSmartData:	the  command  to  read SMART Attribute
		  data failed.
		  FailedReadSmartErrorLog: the command to read the SMART error
		  log failed.
		  FailedReadSmartSelfTestLog:  the  command  to read the SMART
		  self-test log failed.
		  FailedOpenDevice: the open() command to the device failed.

	      SMARTD_ADDRESS
		  is determined by the address argument ADD of the ´-m´ Direc‐
		  tive.	 If ADD is <nomailer>, then SMARTD_ADDRESS is not set.
		  Otherwise, it is set to the  comma-separated-list  of	 email
		  addresses  given  by	the  argument  ADD,  with  the	commas
		  replaced by  spaces  (example:admin@example.com  root).   If
		  more	than one email address is given, then this string will
		  contain space characters and is NOT quoted, so to use it  in
		  a bash script you may want to enclose it in double quotes.

	      SMARTD_MESSAGE
		  is  set  to  the  one sentence summary warning email message
		  string from smartd.	This  message  string  contains	 space
		  characters and is NOT quoted. So to use $SMARTD_MESSAGE in a
		  bash script you should probably enclose it in double quotes.

	      SMARTD_FULLMESSAGE
		  is set to the contents of the entire email  warning  message
		  string  from smartd.	This message string contains space and
		  return  characters  and   is	 NOT   quoted.	 So   to   use
		  $SMARTD_FULLMESSAGE  in  a  bash  script you should probably
		  enclose it in double quotes.

	      SMARTD_TFIRST
		  is a text string giving the time and date at which the first
		  problem of this type was reported. This text string contains
		  space characters and no newlines, and	 is  NOT  quoted.  For
		  example:
		  Sun Feb  9 14:58:19 2003 CST

	      SMARTD_TFIRSTEPOCH
		  is  an  integer,  which is the unix epoch (number of seconds
		  since Jan 1, 1970) for SMARTD_TFIRST.

	      The shell which is used to run  PATH  is	system-dependent.  For
	      vanilla  Linux/glibc  it´s bash. For other systems, the man page
	      for popen(3) should say what shell is used.

	      If the ´-m ADD´ Directive is given with a normal	address	 argu‐
	      ment,  then  the	executable pointed to by PATH will be run in a
	      shell with STDIN receiving the body of the  email	 message,  and
	      with the same command-line arguments:
	      -s "$SMARTD_SUBJECT" $SMARTD_ADDRESS
	      that would normally be provided to ´mail´.  Examples include:
	      -m user@home -M exec /bin/mail
	      -m admin@work -M exec /usr/local/bin/mailto
	      -m root -M exec /Example_1/bash/script/below

	      Note that on Windows, the syntax of the ´Blat´ mailer is used:
	      - -q -subject "$SMARTD_SUBJECT" -to "$SMARTD_ADDRESS"

	      If  the  ´-m  ADD´  Directive  is given with the special address
	      argument <nomailer> then the executable pointed to  by  PATH  is
	      run  in a shell with no STDIN and no command-line arguments, for
	      example:
	      -m <nomailer> -M exec /Example_2/bash/script/below
	      If the executable produces any STDERR/STDOUT output, then smartd
	      assumes  that  something	is  going wrong, and a snippet of that
	      output will be copied to SYSLOG.	The remainder of the output is
	      then discarded.

	      Some  EXAMPLES  of  scripts  that can be used with the ´-M exec´
	      Directive are given below. Some sample scripts are also included
	      in /usr/share/doc/smartmontools/examplescripts/.

       -f     Check   for   ´failure´  of  any	Usage  Attributes.   If	 these
	      Attributes are less than or equal to the threshold, it does  NOT
	      indicate	imminent disk failure.	It "indicates an advisory con‐
	      dition where the usage or age of the  device  has	 exceeded  its
	      intended	design life period."  [Please see the smartctl -A com‐
	      mand-line option.]

       -p     Report anytime that a Prefail Attribute has  changed  its	 value
	      since  the  last check, 30 minutes ago. [Please see the smartctl
	      -A command-line option.]

       -u     Report anytime that a Usage  Attribute  has  changed  its	 value
	      since  the  last check, 30 minutes ago. [Please see the smartctl
	      -A command-line option.]

       -t     Equivalent to turning on the two previous flags ´-p´  and	 ´-u´.
	      Tracks  changes  in  all	device Attributes (both Prefailure and
	      Usage). [Please see the smartctl -A command-line option.]

       -i ID  Ignore device Attribute number ID when checking for  failure  of
	      Usage  Attributes.   ID  must  be a decimal integer in the range
	      from 1 to 255.  This Directive modifies the behavior of the ´-f´
	      Directive and has no effect without it.

	      This  is	useful,	 for  example, if you have a very old disk and
	      don´t want to keep getting messages about the  hours-on-lifetime
	      Attribute	 (usually  Attribute  9)  failing.  This Directive may
	      appear multiple times for a single device, if you want to ignore
	      multiple Attributes.

       -I ID  Ignore   device  Attribute  ID  when  tracking  changes  in  the
	      Attribute values.	 ID must be a decimal  integer	in  the	 range
	      from  1  to  255.	  This	Directive modifies the behavior of the
	      ´-p´, ´-u´, and ´-t´ tracking Directives and has no effect with‐
	      out one of them.

	      This  is useful, for example, if one of the device Attributes is
	      the disk temperature (usually Attribute 194 or 231). It´s annoy‐
	      ing  to  get  reports  each  time the temperature changes.  This
	      Directive may appear multiple times for a single device, if  you
	      want to ignore multiple Attributes.

       -r ID[!]
	      When  tracking,  report the Raw value of Attribute ID along with
	      its (normally reported) Normalized value.	 ID must be a  decimal
	      integer in the range from 1 to 255.  This Directive modifies the
	      behavior of the ´-p´, ´-u´, and ´-t´ tracking Directives and has
	      no effect without one of them.  This Directive may be given mul‐
	      tiple times.

	      A common use of this Directive is to track the  device  Tempera‐
	      ture (often ID=194 or 231).

	      If the optional flag ´!´ is appended, a change of the Normalized
	      value is considered critical.  The  report  will	be  logged  as
	      LOG_CRIT and a warning email will be sent if ´-m´ is specified.

       -R ID[!]
	      When  tracking,  report  whenever	 the Raw value of Attribute ID
	      changes.	(Normally smartd only tracks/reports  changes  of  the
	      Normalized  Attribute  values.)  ID must be a decimal integer in
	      the range from 1 to 255.	This Directive modifies	 the  behavior
	      of  the  ´-p´,  ´-u´,  and  ´-t´	tracking Directives and has no
	      effect without one of them.  This Directive may be given	multi‐
	      ple times.

	      If  this	Directive  is given, it automatically implies the ´-r´
	      Directive for the same Attribute, so that the Raw value  of  the
	      Attribute is reported.

	      A	 common	 use of this Directive is to track the device Tempera‐
	      ture (often ID=194 or 231).  It is also useful for understanding
	      how  different  types  of	 system behavior affects the values of
	      certain Attributes.

	      If the optional flag ´!´ is appended, a change of the Raw	 value
	      is  considered  critical.	 The report will be logged as LOG_CRIT
	      and a warning email will be sent if ´-m´ is specified.  An exam‐
	      ple is ´-R 5!´ to warn when new sectors are reallocated.

       -C ID[+]
	      [ATA  only]  Report  if the current number of pending sectors is
	      non-zero.	 Here ID is the id number of the Attribute  whose  raw
	      value is the Current Pending Sector count.  The allowed range of
	      ID is 0 to 255 inclusive.	  To  turn  off	 this  reporting,  use
	      ID = 0.	If  the -C ID option is not given, then it defaults to
	      -C 197 (since Attribute 197 is generally used to monitor pending
	      sectors).	  If  the  name	 of this Attribute is changed by a ´-v
	      197,FORMAT,NAME´ directive, the default is changed to -C 0.

	      If ´+´ is specified, a report is only printed if the  number  of
	      sectors  has  increased  between two check cycles. Some disks do
	      not reset this attribute when a bad sector is reallocated.   See
	      also ´-v 197,increasing´ below.

	      A	 pending sector is a disk sector (containing 512 bytes of your
	      data) which the device would like to mark as ``bad" and  reallo‐
	      cate.   Typically	 this  is  because your computer tried to read
	      that sector, and the read failed because the data on it has been
	      corrupted	 and  has  inconsistent	 Error Checking and Correction
	      (ECC) codes.  This is important to know, because it  means  that
	      there  is some unreadable data on the disk.  The problem of fig‐
	      uring out what file this data belongs to is operating system and
	      file  system  specific.	You  can typically force the sector to
	      reallocate by writing to it (translation: make the  device  sub‐
	      stitute a spare good sector for the bad one) but at the price of
	      losing the 512 bytes of data stored there.

       -U ID[+]
	      [ATA only] Report if the number of offline uncorrectable sectors
	      is  non-zero.   Here  ID is the id number of the Attribute whose
	      raw value	 is  the  Offline  Uncorrectable  Sector  count.   The
	      allowed  range  of  ID  is 0 to 255 inclusive.  To turn off this
	      reporting, use ID = 0.  If the -U ID option is not  given,  then
	      it  defaults to -U 198 (since Attribute 198 is generally used to
	      monitor offline uncorrectable sectors).  If  the	name  of  this
	      Attribute	 is  changed  by  a  ´-v  198,FORMAT,NAME´ (except ´-v
	      198,FORMAT,Offline_Scan_UNC_SectCt´), directive, the default  is
	      changed to -U 0.

	      If  ´+´  is specified, a report is only printed if the number of
	      sectors has increased since the last check cycle. Some disks  do
	      not  reset this attribute when a bad sector is reallocated.  See
	      also ´-v 198,increasing´ below.

	      An offline uncorrectable sector is a disk sector which  was  not
	      readable during an off-line scan or a self-test.	This is impor‐
	      tant to know, because if you have data stored in this disk  sec‐
	      tor,  and	 you  need to read it, the read will fail.  Please see
	      the previous ´-C´ option for more details.

       -W DIFF[,INFO[,CRIT]]
	      Report if the current temperature had changed by at  least  DIFF
	      degrees  since  last report, or if new min or max temperature is
	      detected.	 Report or Warn if the temperature is greater or equal
	      than  one of INFO or CRIT degrees Celsius.  If the limit CRIT is
	      reached, a message with loglevel ´LOG_CRIT´ will	be  logged  to
	      syslog and a warning email will be send if '-m' is specified. If
	      only  the	 limit	INFO  is  reached,  a  message	with  loglevel
	      ´LOG_INFO´ will be logged.

	      If  this directive is used in conjunction with state persistence
	      (´-s´ option), the min and max temperature values are  preserved
	      across boot cycles. The minimum temperature value is not updated
	      during the first 30 minutes after startup.

	      To disable any of the 3 reports, set the corresponding limit  to
	      0.  Trailing zero arguments may be omitted. By default, all tem‐
	      perature reports are disabled (´-W 0´).

	      To track temperature changes of at least 2 degrees, use:
	       -W 2
	      To log informal messages on temperatures of at least 40 degrees,
	      use:
	       -W 0,40
	      For  warning  messages/mails  on	temperatures  of  at  least 45
	      degrees, use:
	       -W 0,0,45
	      To combine all of the above reports, use:
	       -W 2,40,45

	      For ATA devices, smartd interprets Attribute 194 as  Temperature
	      Celsius by default. This can be changed to Attribute 9 or 220 by
	      the drive database or by the ´-v´ directive, see below.

       -F TYPE
	      [ATA only] Modifies the behavior of  smartd  to  compensate  for
	      some known and understood device firmware bug.  The arguments to
	      this Directive are exclusive, so that only the  final  Directive
	      given is used.  The valid values are:

	      none  - Assume that the device firmware obeys the ATA specifica‐
	      tions.  This is the default, unless the device has  presets  for
	      ´-F´ in the device database.

	      samsung - In some Samsung disks (example: model SV4012H Firmware
	      Version: RM100-08) some of the two- and four-byte quantities  in
	      the  SMART data structures are byte-swapped (relative to the ATA
	      specification).  Enabling this option tells smartd  to  evaluate
	      these  quantities	 in byte-reversed order.  Some signs that your
	      disk needs this option are (1) no self-test  log	printed,  even
	      though  you  have	 run self-tests; (2) very large numbers of ATA
	      errors reported in the ATA error log; (3) strange and impossible
	      values for the ATA error log timestamps.

	      samsung2	-  In  some  Samsung  disks  the  number of ATA errors
	      reported is byte swapped.	 Enabling this option tells smartd  to
	      evaluate this quantity in byte-reversed order.

	      samsung3	-  Some	 Samsung disks (at least SP2514N with Firmware
	      VF100-37) report a self-test still in progress with 0% remaining
	      when the test was already completed. If this directive is speci‐
	      fied, smartd will not skip the  next  scheduled  self-test  (see
	      Directive ´-s´ above) in this case.

	      Note  that  an explicit ´-F´ Directive will over-ride any preset
	      values for ´-F´ (see the ´-P´ option below).

	      [Please see the smartctl -F command-line option.]

       -v ID,FORMAT[:BYTEORDER][,NAME]
	      [ATA only] Sets a vendor-specific raw  value  print  FORMAT,  an
	      optional	BYTEORDER and an optional NAME for Attribute ID.  This
	      directive may be used multiple times.  Please  see  smartctl  -v
	      command-line option for further details.

	      The following arguments affect smartd warning output:

	      197,increasing  - Raw Attribute number 197 (Current Pending Sec‐
	      tor Count) is not reset if  uncorrectable	 sectors  are  reallo‐
	      cated.  This sets ´-C 197+´ if no other ´-C´ directive is speci‐
	      fied.

	      198,increasing - Raw Attribute number 198 (Offline Uncorrectable
	      Sector  Count)  is not reset if uncorrectable sector are reallo‐
	      cated.  This sets ´-U 198+´ if no other ´-U´ directive is speci‐
	      fied.

       -P TYPE
	      Specifies	 whether smartd should use any preset options that are
	      available for this drive.	 The valid arguments to this Directive
	      are:

	      use  -  use any presets that are available for this drive.  This
	      is the default.

	      ignore - do not use any presets for this drive.

	      show - show the presets listed for this drive in the database.

	      showall - show the presets that are available for all drives and
	      then exit.

	      [Please see the smartctl -P command-line option.]

       -a     Equivalent  to  turning on all of the following Directives: ´-H´
	      to check the SMART health status, ´-f´  to  report  failures  of
	      Usage (rather than Prefail) Attributes, ´-t´ to track changes in
	      both Prefailure and Usage Attributes,  ´-l selftest´  to	report
	      increases	 in  the number of Self-Test Log errors, ´-l error´ to
	      report increases in the number of ATA errors, ´-C 197´ to report
	      nonzero values of the current pending sector count, and ´-U 198´
	      to report nonzero values of the offline pending sector count.

	      Note that -a is the default for ATA devices.  If none  of	 these
	      other Directives is given, then -a is assumed.

       #      Comment: ignore the remainder of the line.

       \      Continuation  character:	if  this is the last non-white or non-
	      comment character on a line, then the following line is  a  con‐
	      tinuation of the current one.

       If  you	are  not sure which Directives to use, I suggest experimenting
       for a few minutes with smartctl to see what  SMART  functionality  your
       disk(s)	support(s).   If you do not like voluminous syslog messages, a
       good choice of smartd configuration file Directives might be:
       -H -l selftest -l error -f.
       If you want more frequent information, use: -a.

       If a cciss controller is	 used  then  the  corresponding	 block	device
       (/dev/cciss/c?d?) must be listed, along with the ´-d cciss,N´ Directive
       (see below).

       ADDITIONAL DETAILS ABOUT DEVICESCAN
	      If a non-comment entry in the configuration  file	 is  the  text
	      string  DEVICESCAN  in  capital letters, then smartd will ignore
	      any remaining lines in the configuration file, and will scan for
	      devices.

	      [NEW  EXPERIMENTAL  SMARTD  FEATURE]  Configuration  entries for
	      devices not found by the platform-specific device	 scanning  may
	      precede the DEVICESCAN entry.

	      If  DEVICESCAN  is  not  followed by any Directives, then smartd
	      will scan for both ATA and SCSI devices, and  will  monitor  all
	      possible SMART properties of any devices that are found.

	      DEVICESCAN  may  optionally be followed by any valid Directives,
	      which will be applied to all devices that are found in the scan.
	      For example
	      DEVICESCAN -m root@example.com
	      will  scan for all devices, and then monitor them.  It will send
	      one email warning per device for any problems that are found.
	      DEVICESCAN -d ata -m root@example.com
	      will do the same, but restricts the scan to ATA devices only.
	      DEVICESCAN -H -d ata -m root@example.com
	      will do the same, but only monitors the SMART health  status  of
	      the  devices,  (rather  than  the default -a, which monitors all
	      SMART properties).

       EXAMPLES OF SHELL SCRIPTS FOR ´-M exec´
	      These are two examples of shell scripts that can	be  used  with
	      the ´-M exec PATH´ Directive described previously.  The paths to
	      these scripts and similar executables is the  PATH  argument  to
	      the ´-M exec PATH´ Directive.

	      Example  1:  This	 script	 is  for  use with ´-m ADDRESS -M exec
	      PATH´.  It appends the output of smartctl -a to  the  output  of
	      the smartd email warning message and sends it to ADDRESS.

	      #! /bin/bash

	      # Save the email message (STDIN) to a file:
	      cat > /root/msg

	      # Append the output of smartctl -a to the message:
	      /usr/sbin/smartctl -a -d $SMART_DEVICETYPE $SMARTD_DEVICE >> /root/msg

	      # Now email the message to the user at address ADD:
	      /bin/mail -s "$SMARTD_SUBJECT" $SMARTD_ADDRESS < /root/msg

	      Example  2:  This	 script is for use with ´-m <nomailer> -M exec
	      PATH´. It warns all users about a disk problem,  waits  30  sec‐
	      onds, and then powers down the machine.

	      #! /bin/bash

	      # Warn all users of a problem
	      wall ´Problem detected with disk: ´ "$SMARTD_DEVICESTRING"
	      wall ´Warning message from smartd is: ´ "$SMARTD_MESSAGE"
	      wall ´Shutting down machine in 30 seconds... ´

	      # Wait half a minute
	      sleep 30

	      # Power down the machine
	      /sbin/shutdown -hf now

	      Some  example  scripts  are  distributed	with the smartmontools
	      package, in /usr/share/doc/smartmontools/examples/.

	      Please note that these scripts typically run  as	root,  so  any
	      files  that  they	 read/write should not be writable by ordinary
	      users or reside in directories like /tmp that  are  writable  by
	      ordinary users and may expose your system to symlink attacks.

	      As  previously  described,  if  the  scripts  write to STDOUT or
	      STDERR, this is interpreted as  indicating  that	there  was  an
	      internal error within the script, and a snippet of STDOUT/STDERR
	      is logged to SYSLOG.  The remainder is flushed.

NOTES
       smartd will make log entries at loglevel	 LOG_INFO  if  the  Normalized
       SMART  Attribute values have changed, as reported using the ´-t´, ´-p´,
       or ´-u´ Directives. For example:
       ´Device: /dev/hda, SMART Attribute: 194 Temperature_Celsius changed from 94 to 93´
       Note that in this message, the value given is the ´Normalized´ not  the
       ´Raw´  Attribute	 value	(the disk temperature in this case is about 22
       Celsius).  The ´-R´ and ´-r´ Directives modify this behavior,  so  that
       the information is printed with the Raw values as well, for example:
       ´Device: /dev/hda, SMART Attribute: 194 Temperature_Celsius changed from 94 [Raw 22] to 93 [Raw 23]´
       Here  the  Raw values are the actual disk temperatures in Celsius.  The
       way in which the Raw values are printed, and the names under which  the
       Attributes  are	reported,  is governed by the various ´-v Num,Descrip‐
       tion´ Directives described previously.

       Please see the smartctl manual page for further explanation of the dif‐
       ferences between Normalized and Raw Attribute values.

       smartd  will make log entries at loglevel LOG_CRIT if a SMART Attribute
       has failed, for example:
       ´Device: /dev/hdc, Failed SMART Attribute: 5 Reallocated_Sector_Ct´
	This loglevel  is  used	 for  reporting	 enabled  by  the  ´-H´,  -f´,
       ´-l selftest´,  and ´-l error´ Directives. Entries reporting failure of
       SMART Prefailure Attributes should not be ignored: they mean  that  the
       disk is failing.	 Use the smartctl utility to investigate.

       Under Solaris with the default /etc/syslog.conf configuration, messages
       below loglevel LOG_NOTICE will not be recorded.	Hence all smartd  mes‐
       sages  with  loglevel  LOG_INFO	will  be lost.	If you want to use the
       existing daemon facility to log all messages from  smartd,  you	should
       change /etc/syslog.conf from:
	      ...;daemon.notice;...	   /var/adm/messages
       to read:
	      ...;daemon.info;...	   /var/adm/messages
       Alternatively, you can use a local facility to log messages: please see
       the smartd '-l' command-line option described above.

       On Cygwin and Windows, the log messages are written to the event log or
       to  a  file.  See  documentation	 of the '-l FACILITY' option above for
       details.

       On Windows, the following built-in commands  can	 be  used  to  control
       smartd, if running as a daemon:

       ´smartd status´ - check status

       ´smartd stop´ - stop smartd

       ´smartd reload´ - reread config file

       ´smartd restart´ - restart smartd

       ´smartd sigusr1´ - check disks now

       ´smartd sigusr2´ - toggle debug mode

       On WinNT4/2000/XP, smartd can also be run as a Windows service:

       The  Cygwin Version of smartd can be run as a service via the cygrunsrv
       tool. The start-up script provides Cygwin-specific commands to  install
       and remove the service:
       /etc/init.d/smartd install [options]
       /etc/init.d/smartd remove
       The  service can be started and stopped by the start-up script as usual
       (see EXAMPLES above).

       The Windows Version of smartd has buildin support for services:

       ´smartd install [options]´ installs a service named  "smartd"  (display
       name  "SmartD Service") using the command line ´/installpath/smartd.exe
       --service [options]´.

       ´smartd remove´ can later be used to remove the service entry from reg‐
       istry.

       Upon  startup,  the smartd service changes the working directory to its
       own installation path. If smartd.conf and blat.exe are stored  in  this
       directory, no ´-c´ option and ´-M exec´ directive is needed.

       The debug mode (´-d´, ´-q onecheck´) does not work if smartd is running
       as service.

       The service can be controlled as usual with Windows commands  ´net´  or
       ´sc´ (´net start smartd´, ´net stop smartd´).

       Pausing the service (´net pause smartd´) sets the interval between disk
       checks (´-i N´) to infinite.

       Continuing the paused service (´net continue smartd´) resets the inter‐
       val and rereads the configuration file immediately (like SIGHUP):

       Continuing  a still running service (´net continue smartd´ without pre‐
       ceding ´net pause smartd´) does not  reread  configuration  but	checks
       disks immediately (like SIGUSR1).

LOG TIMESTAMP TIMEZONE
       When smartd makes log entries, these are time-stamped.  The time stamps
       are in the computer's local time zone, which  is	 generally  set	 using
       either  the environment variable ´TZ´ or using a time-zone file such as
       /etc/localtime.	You may wish to change the timezone  while  smartd  is
       running	(for  example,	if  you	 carry a laptop to a new time-zone and
       don't reboot it).  Due to a bug in the tzset(3) function of  many  unix
       standard	 C libraries, the time-zone stamps of smartd might not change.
       For some systems, smartd will work around this problem if the time-zone
       is  set using /etc/localtime. The work-around fails if the time-zone is
       set using the ´TZ´ variable (or a file that it points to).

RETURN VALUES
       The return value (exit status) of smartd can have the following values:

       0:     Daemon startup successful, or smartd was killed by a SIGTERM (or
	      in debug mode, a SIGQUIT).

       1:     Commandline did not parse.

       2:     There was a syntax error in the config file.

       3:     Forking the daemon failed.

       4:     Couldn´t create PID file.

       5:     Config  file  does  not exist (only returned in conjunction with
	      the ´-c´ option).

       6:     Config file exists, but cannot be read.

       8:     smartd ran out of memory during startup.

       9:     A compile time constant of smartd was too small.	 This  can  be
	      caused  by  an  excessive	 number	 of  disks,  or	 by  lines  in
	      /etc/smartd.conf that are too long.  Please report this  problem
	      to  smartmontools-support@lists.sourceforge.net.

       10     An inconsistency was found in smartd´s internal data structures.
	      This should never happen.	 It must be due to either a coding  or
	      compiler bug.  Please report such failures to smartmontools-sup‐
	      port@lists.sourceforge.net.

       16:    A device explicitly listed in /etc/smartd.conf  can´t  be	 moni‐
	      tored.

       17:    smartd didn´t find any devices to monitor.

       254:   When in daemon mode, smartd received a SIGINT or SIGQUIT.	 (Note
	      that in debug mode, SIGINT has the same effect  as  SIGHUP,  and
	      makes smartd reload its configuration file. SIGQUIT has the same
	      effect as SIGTERM and causes smartd to exit with zero exit  sta‐
	      tus.

       132 and above
	      smartd  was  killed  by  a  signal that is not explicitly listed
	      above.  The exit status is then 128 plus the signal number.  For
	      example  if smartd is killed by SIGKILL (signal 9) then the exit
	      status is 137.

AUTHOR
       Bruce Allen smartmontools-support@lists.sourceforge.net
       University of Wisconsin - Milwaukee Physics Department

CONTRIBUTORS
       The following have made large contributions to smartmontools:
       Casper Dik (Solaris SCSI interface)
       Christian Franke (Windows interface, C++ redesign, USB support, ...)
       Douglas Gilbert (SCSI subsystem)
       Guido Guenther (Autoconf/Automake packaging)
       Geoffrey Keating (Darwin ATA interface)
       Eduard Martinescu (FreeBSD interface)
       Frederic L. W. Meunier (Web site and Mailing list)
       Gabriele Pohl (Web site and Wiki, conversion from CVS to SVN)
       Keiji Sawada (Solaris ATA interface)
       Manfred Schwarb (Drive database)
       Sergey Svishchev (NetBSD interface)
       David Snyder and Sergey Svishchev (OpenBSD interface)
       Phil Williams (User interface and drive database)
       Shengfeng Zhou (Linux/FreeBSD HighPoint RocketRAID interface)
       Many other individuals have made smaller contributions and corrections.

CREDITS
       This code was derived from the smartsuite package, written  by  Michael
       Cornwell,  and  from  the previous UCSC smartsuite package.  It extends
       these to cover ATA-5 disks.  This code was originally  developed	 as  a
       Senior  Thesis by Michael Cornwell at the Concurrent Systems Laboratory
       (now part of the Storage Systems Research Center), Jack	Baskin	School
       of    Engineering,    University	   of	 California,	Santa	 Cruz.
       http://ssrc.soe.ucsc.edu/ .

HOME PAGE FOR SMARTMONTOOLS:
       Please see the following web site for updates,  further	documentation,
       bug reports and patches: http://smartmontools.sourceforge.net/

SEE ALSO:
       smartd.conf(5),	smartctl(8), syslogd(8), syslog.conf(5), badblocks(8),
       ide-smart(8), regex(7).

REFERENCES FOR SMART
       An introductory article about smartmontools is  Monitoring  Hard	 Disks
       with  SMART,  by Bruce Allen, Linux Journal, January 2004, pages 74-77.
       This is http://www.linuxjournal.com/article/6983 online.

       If you would like to understand better how SMART	 works,	 and  what  it
       does,  a good place to start is with Sections 4.8 and 6.54 of the first
       volume of the ´AT Attachment  with  Packet  Interface-7´	 (ATA/ATAPI-7)
       specification  Revision	4b.   This  documents  the SMART functionality
       which the smartmontools utilities provide access to.   This  and	 other
       versions	 of  this  Specification  are  available from the T13 web site
       http://www.t13.org/ .

       The functioning of SMART was originally defined by the SFF-8035i	 revi‐
       sion 2 and the SFF-8055i revision 1.4 specifications.  These are publi‐
       cations of the Small Form Factors (SFF) Committee.

       Links to these and other documents may be found on the  Links  page  of
       the  smartmontools  Wiki	 at http://sourceforge.net/apps/trac/smartmon‐
       tools/wiki/Links .

SVN ID OF THIS PAGE:
       $Id: smartd.8.in 3117 2010-06-08 15:41:04Z chrfranke $

smartmontools-5.40		  2010-07-12			     SMARTD(8)
[top]

List of man pages available for Raspbian

Copyright (c) for man pages and the logo by the respective OS vendor.

For those who want to learn more, the polarhome community provides shell access and support.

[legal] [privacy] [GNU] [policy] [cookies] [netiquette] [sponsors] [FAQ]
Tweet
Polarhome, production since 1999.
Member of Polarhome portal.
Based on Fawad Halim's script.
....................................................................
Vote for polarhome
Free Shell Accounts :: the biggest list on the net