pci_error_tolerance_time man page on HP-UX

Man page or keyword search:  
man Server   10987 pages
apropos Keyword Search (all sections)
Output format
HP-UX logo
[printable version]

pci_error_tolerance_time(5)			   pci_error_tolerance_time(5)

NAME
       pci_error_tolerance_time	 -  time interval, in minutes, between two PCI
       errors at a I/O slot that will result in automatic PCI Error Recovery

VALUES
   Default
   Allowed values
       (disabled) or non-zero (enabled)

   Recommended values
DESCRIPTION
       is a dynamic tunable that corresponds to time interval in minutes.   It
       determines  whether an automatic PCI Error Recovery should be initiated
       or not between two PCI errors occurring at an I/O  slot.	  If  two  PCI
       errors  occur  at  a  slot within this specified time interval, the PCI
       card in the slot will be suspended and  a  manual  PCI  Error  Recovery
       operation will have to be performed to make the card functional.	 Refer
       to the section of the olrad(1M) manpage for more details regarding  the
       manual PCI Error Recovery operation.

   Who Is Expected to Change This Tunable?
       System administrators can change the value of based on the frequency of
       PCI errors seen in the system.

   Restrictions on Changing
       None.  This tunable is dynamic.	Changes to this	 tunable  take	effect
       immediately.

WARNINGS
       All HP-UX kernel tunable parameters are release specific.  This parame‐
       ter may be removed or have its meaning changed in  future  releases  of
       HP-UX.

       Installation of optional kernel software, from HP or other vendors, may
       cause changes to tunable parameter values.   After  installation,  some
       tunable	parameters may no longer be at the default or recommended val‐
       ues.  For information about the effects of installation on tunable val‐
       ues, consult the documentation for the kernel software being installed.
       For  information	 about	optional  kernel  software  that  was  factory
       installed on your system, see at

AUTHOR
       was developed by HP.

SEE ALSO
       olrad(1M).

       available under the section at

			   Tunable Kernel Parameterpci_error_tolerance_time(5)
[top]

List of man pages available for HP-UX

Copyright (c) for man pages and the logo by the respective OS vendor.

For those who want to learn more, the polarhome community provides shell access and support.

[legal] [privacy] [GNU] [policy] [cookies] [netiquette] [sponsors] [FAQ]
Tweet
Polarhome, production since 1999.
Member of Polarhome portal.
Based on Fawad Halim's script.
....................................................................
Vote for polarhome
Free Shell Accounts :: the biggest list on the net