IODINE(8)							     IODINE(8)

NAME
       iodine, iodined - tunnel IPv4 over DNS

SYNOPSIS
       iodine [-v]

       iodine [-h]

       iodine [-4] [-6] [-f] [-r] [-u user ] [-P password ] [-m fragsize ] [-t
       chrootdir ] [-d device ] [-R rdomain ] [-m fragsize ] [-M namelen ] [-z
       context	]  [-F	pidfile	 ]  [-T	 dnstype ] [-O downenc ] [-L 0|1 ] [-I
       interval ] [ nameserver ] topdomain

       iodined [-v]

       iodined [-h]

       iodined [-c] [-s] [-f] [-D] [-u user ] [-t chrootdir ] [-d device ] [-m
       mtu  ]  [-l  listen_ip  ]  [-p  port ] [-n ( auto | external_ip ) ] [-b
       dnsport ] [-P password ] [-z context ] [-F pidfile ] [-i	 max_idle_time
       ] tunnel_ip [ /netmask ] topdomain

DESCRIPTION
       iodine lets you tunnel IPv4 data through a DNS server. This can be use‐
       ful in situations where Internet access is firewalled, but DNS  queries
       are  allowed.  It  needs	 a TUN/TAP device to operate. The bandwidth is
       asymmetrical, with a measured maximum of 680 kbit/s  upstream  and  2.3
       Mbit/s  downstream  in  a  wired LAN test network.  Realistic sustained
       throughput on a Wifi network using a carrier-grade DNS cache  has  been
       measured	 at  some  50  kbit/s upstream and over 200 kbit/s downstream.
       iodine is the client application, iodined is the server.

       Note: server and client are required to speak the exact same  protocol.
       In  most	 cases,	 this  means running the same iodine version. Unfortu‐
       nately, implementing backward and  forward  protocol  compatibility  is
       usually not feasible.

OPTIONS
   Common Options:
       -v     Print version info and exit.

       -h     Print usage info and exit.

       -f     Keep running in foreground.

       -u user
	      Drop privileges and run as user 'user' after setting up tunnel.

       -t chrootdir
	      Chroot to 'chrootdir' after setting up tunnel.

       -d device
	      Use  the TUN device 'device' instead of the normal one, which is
	      dnsX on Linux and otherwise tunX.

       -P password
	      Use 'password' to authenticate. If not used, stdin will be  used
	      as input. Only the first 32 characters will be used.

       -z context
	      Apply SELinux 'context' after initialization.

       -F pidfile
	      Create 'pidfile' and write process id in it.

   Client Options:
       -4     Force IPv4 DNS queries

       -6     Force IPv6 DNS queries

       -r     Skip raw UDP mode. If not used, iodine will try getting the pub‐
	      lic IP address of the iodined host and test if it	 is  reachable
	      directly.	 If  it is, traffic will be sent to the server instead
	      of the DNS relay.

       -R rdomain
	      Use OpenBSD routing domain 'rdomain' for the DNS connection.

       -m fragsize
	      Force maximum downstream fragment size. Not  setting  this  will
	      cause  the  client  to  automatically probe the maximum accepted
	      downstream fragment size.

       -M namelen
	      Maximum length of upstream hostnames, default 255.  Usable range
	      ca.  100	to  255.  Use this option to scale back upstream band‐
	      width in favor of downstream bandwidth.	Also  useful  for  DNS
	      servers  that  perform  unreliably  when using full-length host‐
	      names, noticeable when fragment size autoprobe returns very dif‐
	      ferent results each time.

       -T dnstype
	      DNS request type override.  By default, autodetection will probe
	      for working DNS request types, and will select the request  type
	      that is expected to provide the most bandwidth.  However, it may
	      turn out that a DNS relay imposes limits that skew the  picture,
	      which  may  lead	to  an "unexpected" DNS request type providing
	      more bandwidth.  In that case, use this option to	 override  the
	      autodetection.   In  (expected)  decreasing bandwidth order, the
	      supported DNS request types are: NULL, PRIVATE,  TXT,  SRV,  MX,
	      CNAME and A (returning CNAME).  Note that SRV, MX and A may/will
	      cause additional lookups by "smart" caching nameservers  to  get
	      an  actual  IP  address, which may either slow down or fail com‐
	      pletely. The PRIVATE type uses value 65399 (in the 'private use'
	      range) and requires servers implementing RFC 3597.

       -O downenc
	      Force  downstream	 encoding  type	 for  all query type responses
	      except NULL.  Default is autodetected,  but  may	not  spot  all
	      problems for the more advanced codecs.  Use this option to over‐
	      ride the autodetection.  Base32 is the  lowest-grade  codec  and
	      should  always  work;  this  is  used  when autodetection fails.
	      Base64 provides more bandwidth, but may not work	on  all	 name‐
	      servers.	 Base64u is equal to Base64 except in using underscore
	      ('_') instead of plus sign ('+'), possibly working where	Base64
	      does  not.   Base128 uses high byte values (mostly accented let‐
	      ters in iso8859-1), which might work with some nameservers.  For
	      TXT queries, Raw will provide maximum performance, but this will
	      only work if  the	 nameserver  path  is  fully  8-bit-clean  for
	      responses that are assumed to be "legible text".

       -L 0|1 Lazy-mode	 switch.   -L1	(default):  Use lazy mode for improved
	      performance and decreased latency.  A very small minority of DNS
	      relays appears to be unable to handle the lazy mode traffic pat‐
	      tern, resulting in no or very little data coming	through.   The
	      iodine  client will detect this and try to switch back to legacy
	      mode, but this may not always work.  In these situations use -L0
	      to force running in legacy mode (implies -I1).

       -I interval
	      Maximum  interval	 between requests (pings) so that intermediate
	      DNS servers will not time out. Default is 4 in lazy mode,	 which
	      will  work  fine	in  most  cases. When too many SERVFAIL errors
	      occur, iodine will automatically reduce this to 1.  To get abso‐
	      lute minimum DNS traffic, increase well above 4, but not so high
	      that SERVFAIL errors start to occur.  There are some DNS	relays
	      with  very  small timeouts, notably dnsadvantage.com (ultradns),
	      that will give SERVFAIL errors even with -I1;  data  will	 still
	      get  trough,  and	 these	errors can be ignored.	Maximum useful
	      value is 59, since iodined  will	close  a  client's  connection
	      after 60 seconds of inactivity.

   Server Options:
       -c     Disable checking the client IP address on all incoming requests.
	      By default, requests originating from non-matching IP  addresses
	      will be rejected, however this will cause problems when requests
	      are routed via a cluster of DNS servers.

       -s     Don't try to configure IP address or MTU.	 This should  only  be
	      used  if	you  have  already  configured the device that will be
	      used.

       -D     Increase debug level. Level  1  prints  info  about  each	 RX/TX
	      packet.  Implies the -f option.  On level 2 (-DD) or higher, DNS
	      queries will be printed literally.  When using Base128  upstream
	      encoding,	 this  is  best	 viewed as ISO Latin-1 text instead of
	      (illegal) UTF-8.	This is easily	done  with  :  "LC_ALL=C  luit
	      iodined -DD ..."	(see luit(1)).

       -m mtu Set  'mtu' as mtu size for the tun device.  This will be sent to
	      the client on login, and the client will use the	same  mtu  for
	      its  tun	device.	 Default 1130.	Note that the DNS traffic will
	      be automatically fragmented when needed.

       -l listen_ip
	      Make  the	 server	 listen	 only  on  'listen_ip'	for   incoming
	      requests.	  By  default, incoming requests are accepted from all
	      interfaces.

       -p port
	      Make the server listen on 'port' instead of 53 for traffic.   If
	      'listen_ip'  does	 not include localhost, this 'port' can be the
	      same as 'dnsport'.  Note: You must make sure  the	 dns  requests
	      are forwarded to this port yourself.

       -n auto|external_ip
	      The  IP  address to return in NS responses. Default is to return
	      the address used as destination in the query.  If external_ip is
	      'auto',  iodined will use externalip.net web service to retrieve
	      the external IP of the host and use that for NS responses.

       -b dnsport
	      If this port is specified, all incoming requests not inside  the
	      tunnel domain will be forwarded to this port on localhost, to be
	      handled by a real dns.  If 'listen_ip' does not  include	local‐
	      host,  this 'dnsport' can be the same as 'port'.	Note: The for‐
	      warding is not fully transparent, and not	 advised  for  use  in
	      production environments.

       -i max_idle_time
	      Make  the	 server	 stop itself after max_idle_time seconds if no
	      traffic have been received.  This should be combined  with  sys‐
	      temd or upstart on demand activation for being effective.

   Client Arguments:
       nameserver
	      The  nameserver to use to relay the dns traffic. This can be any
	      relaying nameserver or the server running iodined if  reachable.
	      This  field  can	be given as an IPv4/IPv6 address or as a host‐
	      name. This argument is optional, and if not  specified  a	 name‐
	      server will be read from the /etc/resolv.conf file.

       topdomain
	      The  dns	traffic	 will  be sent as queries for subdomains under
	      ´topdomain'. This is normally a subdomain to a domain  you  own.
	      Use  a short domain name to get better throughput. If nameserver
	      is the iodined server, then the topdomain can be chosen  freely.
	      This  argument  must  be	the  same  on  both the client and the
	      server.

   Server Arguments:
       tunnel_ip[/netmask]
	      This is the server's ip address on the tun interface. The client
	      will be given the next ip number in the range. It is recommended
	      to use the 10.0.0.0 or 172.16.0.0 ranges. The default netmask is
	      /27,  can	 be  overridden by specifying it here. Using a smaller
	      network will limit the number of concurrent users.

       topdomain
	      The dns traffic is expected to arrive as queries for  subdomains
	      under  'topdomain'. This is normally a subdomain to a domain you
	      own. Use a short domain name  to	get  better  throughput.  This
	      argument	must  be  the  same on both the client and the server.
	      Queries for domains other than  'topdomain'  will	 be  forwarded
	      when the -b option is given, otherwise they will be dropped.

EXAMPLES
       See  the	 README	 file  for  both a quick test scenario, and a detailed
       description of real-world deployment.

SECURITY
       Login is a relatively secure  challenge-response	 MD5  hash,  with  the
       password	 never	passing	 the  wire.   However,	all  other data is NOT
       encrypted in any way. The DNS traffic is	 also  vulnerable  to  replay,
       injection  and  man-in-the-middle  attacks,  especially when iodined is
       used with the -c option. Use of ssh or vpn tunneling is strongly recom‐
       mended.	On both server and client, use iptables, pf or other firewalls
       to block all traffic coming in from the tun interfaces, except  to  the
       used ssh or vpn ports.

ENVIRONMENT
   IODINE_PASS
       If  the	environment  variable  IODINE_PASS is set, iodine will use the
       value it is set to as password instead of asking for one. The -P option
       still has precedence.

   IODINED_PASS
       If  the	environment variable IODINED_PASS is set, iodined will use the
       value it is set to as password instead of asking for one. The -P option
       still has precedence.

SEE ALSO
       The README file in the source distribution contains some more elaborate
       information.

BUGS
       File bugs at http://dev.kryo.se/iodine/

AUTHORS
       Erik Ekman <yarrick@kryo.se> and Bjorn Andersson <flex@kryo.se>.	 Major
       contributions by Anne Bezemer.

User Manuals			   JUN 2014			     IODINE(8)
[top]

List of man pages available for Kali

Copyright (c) for man pages and the logo by the respective OS vendor.

For those who want to learn more, the polarhome community provides shell access and support.

[legal] [privacy] [GNU] [policy] [cookies] [netiquette] [sponsors] [FAQ]
Tweet
Polarhome, production since 1999.
Member of Polarhome portal.
Based on Fawad Halim's script.
....................................................................
Vote for polarhome
Free Shell Accounts :: the biggest list on the net