drd-unrehost(1M)					      drd-unrehost(1M)

NAME
       drd  unrehost	-  remove  the	system information file, EFI/HPUX/SYS‐
       INFO.TXT, from the EFI partition of a disk previously specified as  the
       target  of a "drd rehost" command, and optionally preserve a copy of it
       in a file on the booted system.

SYNOPSIS
       system_information_file target_device_file] option_file]

DESCRIPTION
       The command removes EFI/HPUX/SYSINFO.TXT, and  optionally  preserves  a
       copy of it in a file on the booted system.

       A  system administrator can execute the command after having previously
       issued the "drd rehost" command, specifying the	same  target,  if  the
       disk should not be rehosted.

       The  format  of the sysinfo file is defined in sysinfo(4). To determine
       the most recent patch that supplies sysinfo(4), please consult the  DRD
       web site, http:docs.hp.comenDRD.

   Options
       recognizes the following options:

	      Displays the usage message.

	      Sets preview mode.

	      Specifies	 the  file  to which the EFI/HPUX/SYSINFO.TXT is to be
	      copied. If not specified, the file is not copied.

	      Decreases the verbosity level by one each time it is  specified.
	      For example,
		     will  reduce the verbosity from the default value of 4 to
		     2.	 If both and are included on  the  command  line,  the
		     effective	verbosity is 2. The minimum verbosity level is
		     0.	 (See also the option).

	      Increases the verbosity level by one each time it is  specified.
	      For example,
		     will  increase  the  effective verbosity from the default
		     value of 4 to 5. If both and are included on the  command
		     line, the effective verbosity is 3. The maximum verbosity
		     level is 5.  (See also the option).

	      Displays the list of possible
		     (extended) options.

	      Sets the extended option to a value.  See	 Extended  -x  Options
	      definitions below.

	      Gets the extended options from a file.

	      Specifies	 the  block  device special file of a single writeable
	      physical disk from whose EFI partition
		     the file EFI/HPUX/SYSINFO.TXT is to be  removed.	If  no
		     target is specified, the inactive system image is used as
		     a target.

   Extended -x Options
       recognizes the following (extended) options:

       Usage: Basic
	      This is the path to the log file for this	 command.   Each  time
	      DRD  is  run,  this file will grow larger.  This can be changed,
	      for example, to a month-specific location for easier  archiving,
	      off-host backup, and rotation.

       Usage: Basic
	      Specifies	 the  level  of message verbosity in the log file (See
	      also -x verbosity).  Legal values are:

	      Only ERROR messages and the startingending BANNER messages.

	      Adds WARNING messages.

	      Adds NOTE messages.

	      Adds INFO messages (informational messages preceded by  the  '*'
	      character).

	      Adds verbose INFO messages.

	      Adds very-verbose INFO messages.

       Usage: Basic
	      This  is the file containing system information attributes, such
	      as hostname and IP address, that is copied to the EFI  partition
	      by   the	 drd   rehost  command	and  consequently  applied  by
	      auto_parms(1M) when the rehosted image is booted. The  file  can
	      be  removed from the EFI partition and optionally copied back to
	      the file system with the drd  unrehost  command.	This  extended
	      option provides the same functionality as the -f option.

       Usage: Basic
	      Specifies the level of stderr verboseness:

	      Only ERROR messages and the startingending BANNER messages.

	      Adds WARNING messages.

	      Adds NOTE messages.

	      Adds  INFO  messages (informational messages preceded by the '*'
	      character).

	      Adds verbose INFO messages.

	      Adds very-verbose INFO messages.

		     Note:  The '-v' option is equivalent to  increasing  ver‐
		     bosity  by	 1  (e.g., from 3 to 4) and the '-q' option is
		     equivalent to decreasing verbosity by 1.	The  '-v'  and
		     '-q' options can be used more than once.

   Return Values
       returns the following values:

	      Success.
	      Error.
	      Warning.

   Examples
       To  remove  EFI/HPUX/SYSINFO.TXT from the EFI partition of the inactive
       system image:

       To remove EFI/HPUX/SYSINFO.TXT from  the	 EFI  partition	 of  the  disk
       /dev/disk/disk9:

       To  remove  EFI/HPUX/SYSINFO.TXT from the EFI partition of the inactive
       system image, preserving a copy at /home/sysadmin/sysinfo_test:

       To remove EFI/HPUX/SYSINFO.TXT from  the	 EFI  partition	 of  the  disk
       /dev/dsk/c0t0d0, preserving a copy at /home/sysadmin/sysinfo_test:

AUTHOR
       was developed by Hewlett-Packard Development Company, L.P.

FILES
       Log file.

SEE ALSO
       auto_parms(1M),	drd(1M),  drd-activate(1M), drd-clone(1M), drd-deacti‐
       vate(1M),  drd-mount(1M),  drd-rehost(1M),   drd-runcmd(1M),   drd-sta‐
       tus(1M), drd-umount(1M), sysinfo(4)

       Dynamic	  Root	  Disk	  Administrator's    Guide,    available    at
       http:docs/hp.comenDRD.

							      drd-unrehost(1M)
[top]

List of man pages available for HP-UX

Copyright (c) for man pages and the logo by the respective OS vendor.

For those who want to learn more, the polarhome community provides shell access and support.