digitemp man page on DragonFly

Man page or keyword search:  
man Server   44335 pages
apropos Keyword Search (all sections)
Output format
DragonFly logo
[printable version]

DIGITEMP(1)							   DIGITEMP(1)

NAME
       digitemp - program to read from 1-wire temperature sensors.

SYNOPSIS
       digitemp [options]

DESCRIPTION
       DigiTemp	 uses  the Dallas 1-wire bus to read temperatures from digital
       sensors attached to a serial port adapter. It handles initializing  the
       bus,  searching	for  attached  devices, reading devices and custom log
       strings. It suports the following temperature devices: DS1820, DS18S20,
       DS18B20, DS1822

       It  also	 handles the DS2406 1-wire hub switches, and DS2422 and DS2423
       counters.

       DigiTemp uses either the DS9097 passive serial  port  adapter,  or  the
       DS2480B	based  DS9097U	adapter. 1-wire adapters from ibuttonlink.com,
       such as the Link45 are also supported.

OPTIONS
       At least 1 action must be given, along with  some  optional  arguments.
       Actions are one (and only on) of the -w -t -a -w options

       -h, -? Show summary of options.

       -v     Show verbose output.

       -i     Initialize  .digitemprc  file,  search the bus for all supported
	      devices.

       -I     Initialize .digitemprc file, search the bus  for	all  supported
	      devices, store devices in sorted serial # order.

       -w     Walk the full device tree and display the serial number and type
	      of all devices detected on the bus.

       -s /dev/cuau0
	      Set serial port to use. Make sure you have permission to	access
	      this port. For USB operation pass USB instead of /dev/cuauX

       -l /var/log/temperature
	      Send  output  to logfile, the output format is defined by the .B
	      -o command

       -c digitemp.conf
	      Set digitemp configuration file. The default is  .digitemprc  in
	      the current directory.

       -r 1000
	      Read  delay  in ms. This sets the amount of time to wait between
	      sending the  temperature	conversion  command  and  reading  the
	      result. The DS18S20 takes about 750mS to do the temperature con‐
	      version. Default is 1000mS (1 sec).

       -t #   Read sensor number #, the # depends on the order of the  sensors
	      in the .digitemprc file.

       -q     Quiet output, no copyright banner.

       -a     Read all sensors.

       -A     Treat DS2438 as A/D converter, output raw voltages and currents.

       -d 5   Delay between samples (in seconds).

       -n 50  Number of times to repeat the command.

       -O"counter format string"
	      See Counter Format below.

       -o [1..3] ["output format string"]
	      See Temperature Format below.

       -H"Humidity format string"
	      See Humidity Format below.

Temperature Format
       The  temperature format can be either a numeric value, or a string. The
       numeric values select pre-configured output formats:

	   1 = One line per sensor, time, C, F (default)
	   2 = One line per sample, elapsed time, temperature in C
	   3 = Same as #2, except temperature is in F

       #2 and #3 have the data seperated by tabs, suitable for import  into  a
       spreadsheet or other graphing software.

       The  format  string  uses  strftime tokens plus 5 special ones for Dig‐
       iTemp:

       %s     for sensor #

       %C     for centigrade

       %F     for fahrenheit

       %R     to output the hex serial number

       %N     for seconds since Epoch.

       The case of the token is important! The default format string  is:  "%b
       %d  %H:%M:%S  Sensor  %s C: %.2C F: %.2F" which gives you an output of:
       May 24 21:25:43 Sensor 0 C: 23.66 F: 74.59

       The DS2438 sensor can be used for a variety of things.  It  includes  a
       temperature  sensor and A/D converter. DigiTemp defaults to using it as
       a humidity sensor. The raw voltages and currents can  be	 displayed  by
       passing the -A argument

       When the -o2 or -o3 log options are used the attached DS2438's tempera‐
       tures will be output without the humidity.

Counter Format String
       The counter format string is similar, adding these tokens:

       %n     is the counter #, which depends on its position in the .digitem‐
	      prc file

       %C     is the count in decimal.

Humidity Format String
       The Humidity format string is the same as the temperature format string
       with the addition of this format specifier:

       %h     is the humidity in 0-100%

AUTHOR
       This manual page was written by Jesús Roncero <jesus@roncero.org>,  for
       the  Debian project (but may be used by others). Modifications by Brian
       C. Lane <bcl@brianlane.com>

UPDATES
       DigiTemp updates can be found on the http://www.digitemp.com website.

				  August 2008			   DIGITEMP(1)
[top]

List of man pages available for DragonFly

Copyright (c) for man pages and the logo by the respective OS vendor.

For those who want to learn more, the polarhome community provides shell access and support.

[legal] [privacy] [GNU] [policy] [cookies] [netiquette] [sponsors] [FAQ]
Tweet
Polarhome, production since 1999.
Member of Polarhome portal.
Based on Fawad Halim's script.
....................................................................
Vote for polarhome
Free Shell Accounts :: the biggest list on the net