DDI_FM_EREPORT_POST(9F)				       DDI_FM_EREPORT_POST(9F)

NAME
       ddi_fm_ereport_post - post an FMA Protocol Error Report Event

SYNOPSIS
       #include <sys/ddifm.h>

       void ddi_fm_ereport_post(dev_info_t *dip, char *ereport_class,
	    uint64_t ena, int *sflag, ... /* name-value pair args */);

INTERFACE LEVEL
       Solaris DDI specific (Solaris DDI)

PARAMETERS
       dip
			Pointer to the dev_info structure

       ereport_class
			FMA Event Protocol error class

       ena
			Error Numeric Association

       sflag
			Determines  whether  caller  can  sleep	 for memory or
			other event resources.

DESCRIPTION
       The ddi_fm_ereport_post() function causes an encoded  fault  management
       error  report  name-value  pair	list  to be queued for delivery to the
       Fault Manager daemon, fmd(1M). The sflag parameter indicates whether or
       not  the	 caller is willing to wait for system memory and event channel
       resources to become available.

       The following ereport_class strings are available for use by  any  leaf
       device driver:

       device.inval_state
			       A  leaf	driver discovers that the device is in
			       an invalid or inconsistent state.  For example,
			       the  driver  might  detect that receive or send
			       ring descriptor indices are corrupted. It might
			       also  find  an invalid value in a register or a
			       driver-to-device protocol violation.

       device.no_response
			       A leaf driver times out waiting for a  response
			       from  the  device.  For	example,  timeouts can
			       occur when no confirmation is seen after reset‐
			       ting,   enabling,  or  disabling	 part  of  the
			       device.

       device.badint_limit
			       A leaf device sends too many consecutive inter‐
			       rupts with no work to do.

       device.intern_corr
			       A leaf device reports to the driver that it has
			       itself detected an internal correctable error.

       device.intern_uncorr
			       A leaf device reports to the driver that it has
			       itself	detected   an  internal	 uncorrectable
			       error.

       device.stall
			       A leaf driver determines that data transmission
			       has stalled indefinitely.

       The ena indicates the Format 1 Error Numeric Association for this error
       report. It might have already been initialized by another error-detect‐
       ing  software  module.  For example, if ddi_fm_ereport_post() is called
       from an error handler callback function, the  fme_ena  field  from  the
       passed-in  ddi_fm_error argument should be used. Otherwise it should be
       set to 0 and will be initialized by ddi_fm_ereport_post().

       The name-value pair args variable argument list contains	 one  or  more
       (names,	type,  value  pointer) nvpair tuples for non-array data_type_t
       types or one or more (name, type, number of  elements,  value  pointer)
       tuples  for  data_type_t	 array	types. There is one mandatory tuple to
       describe the ereport version. This should contain the following values:

	   o	  name - FM_VERSION

	   o	  type - DATA_TYPE_UINT8

	   o	  value - FM_EREPORT_VERS0

       Additional nvpair tuples can describe error conditions for logging pur‐
       poses,  but  are not interpreted by the I/O framework or fault manager.
       The end of the argument list is specified by NULL.

CONTEXT
       The ddi_fm_ereport_post() function can be called from user, kernel,  or
       high-level interrupt context.

ATTRIBUTES
       See attributes(5) for descriptions of the following attributes:

       ┌────────────────────┬─────────────────┐
       │  ATTRIBUTE TYPE    │ ATTRIBUTE VALUE │
       ├────────────────────┼─────────────────┤
       │Interface Stability │ Committed	      │
       └────────────────────┴─────────────────┘

SEE ALSO
       fmd(1M), attributes(5), ddi_fm_service_impact(9F)

				 May 14, 2007	       DDI_FM_EREPORT_POST(9F)
[top]

List of man pages available for SmartOS

Copyright (c) for man pages and the logo by the respective OS vendor.

For those who want to learn more, the polarhome community provides shell access and support.

[legal] [privacy] [GNU] [policy] [cookies] [netiquette] [sponsors] [FAQ]
Tweet
Polarhome, production since 1999.
Member of Polarhome portal.
Based on Fawad Halim's script.
....................................................................
Vote for polarhome
Free Shell Accounts :: the biggest list on the net