CPQARY3(7D)			     2013"			   CPQARY3(7D)

NAME
       cpqary3	-  provides disk and SCSI tape support for HP Smart Array con‐
       trollers

DESCRIPTION
       The cpqary3 module provides low-level interface	routines  between  the
       common  disk  I/O  subsystem  and  the  HP SMART Array controllers. The
       cpqary3 driver provides disk and SCSI tape support  for	the  HP	 Smart
       Array controllers.

       Please  refer  to the cpqary3 release notes, for the supported HP Smart
       Array Controllers and Storage boxes.

       Each controller should be the sole initiator on a SCSI bus.  Auto  con‐
       figuration  code determines if the adapter is present at the Configured
       address and what types of devices are attached to it.

CONFIGURATION
       Use the Array Configuration Utility to configure the controllers.  Each
       controller can support up to 32 logical volumes. In addition, each con‐
       troller supports up to a maximum of  28	connected  SCSI	 tape  drives.
       With 1.90 and later versions of cpqary3 driver, HP Smart Array SAS con‐
       trollers, having Firmware Revision 5.10 or later, will support 64 logi‐
       cal  drives. This firmware also supports Dual Domian Multipath configu‐
       rations.

       The driver attempts to initialize itself in accordance with the	infor‐
       mation found in the configuration file, /kernel/drv/cpqary3.conf.

       New  component  -  hmaeventd which logs the storage events onto console
       and to the Integrated Management Log is made a  part  of	 HPQhma	 5.0.0
       package,	 which	is  not	 part  of the operating system.	 Therefore, by
       default, notify on event functionality is disabled in the  driver  from
       2.1.0  onwards.	 Storage event logging may be enabled in the driver by
       modifying cpqary3.conf to set the cpqary3_noe property to "on".	 Modi‐
       fication	 of  driver properties requires reloading the driver, which in
       most cases will occur only following a reboot of the system.

       The target driver's configuration file shall need entries if support is
       needed for targets numbering greater than the default number of targets
       supported by the corresponding target driver.

       By default, entries for SCSI target numbers 0  to  15  are  present  in
       sd.conf.	  Entries for target numbers 16 and above must be added to the
       'scsi' class in sd.conf to  support  additional	corresponding  logical
       volumes.

       If SCSI tape drives are connected to the supported controllers, entries
       for target IDs from 33 to 33+N must be added in the /kernel/drv/st.conf
       file  under  'scsi'  class,  where  N  is the total number of SCSI tape
       drives connected to the controller with largest number of  tape	drives
       connected  to  it, in the existing configuration. For example, two sup‐
       ported controller, c1 and c2 are present in the system.	If  controller
       c1  has	two (2) tape drives and controller c2 has five (5) tape drives
       connected, then entries for target IDs 33 thru 38  are  required	 under
       'scsi'  class  in  /kernel/drv/st.conf file. The maximum number of tape
       drives that can be connected to a controller is 28. With 1.90 and later
       versions of cpqary3 driver, if tape drives are connected to Smart Array
       SAS controllers, then target ID entries for tape drives from 65 to 65+N
       must be added in /kernel/drv/st.conf file under the 'scsi' class.

FILES
       /kernel/drv/cpqary3.conf - configuration file for CPQary3

SEE ALSO
       driver.conf(4), sd(7D), st(7D)

NOTES
       The  Smart  Array  controllers  supported by the current version of the
       cpqary3 driver do  not  support	'format	 unit'	SCSI  command.	Hence,
       selecting  'format' option under 'format' utility main menu is not sup‐
       ported. In addition, the 'repair' option under  'format'	 utility  main
       menu  is	 not  supported as this operation is not applicable to Logical
       volumes connected to the supported Smart Array controllers.

26,				      Aug			   CPQARY3(7D)
[top]

List of man pages available for SmartOS

Copyright (c) for man pages and the logo by the respective OS vendor.

For those who want to learn more, the polarhome community provides shell access and support.

[legal] [privacy] [GNU] [policy] [cookies] [netiquette] [sponsors] [FAQ]
Tweet
Polarhome, production since 1999.
Member of Polarhome portal.
Based on Fawad Halim's script.
....................................................................
Vote for polarhome
Free Shell Accounts :: the biggest list on the net