EC(4)		       BSD/vax Kernel Interfaces Manual			 EC(4)

NAME
     ec — 3Com 10 Mb/s Ethernet interface

SYNOPSIS
     device ec0 at uba0 csr 161000 vector ecrint eccollide ecxint flags 0

DESCRIPTION
     The ec interface provides access to a 10 Mb/s Ethernet network through a
     3com controller.

     The hardware has 32 kilobytes of dual-ported memory on the UNIBUS.	 This
     memory is used for internal buffering by the board, and the interface
     code reads the buffer contents directly through the UNIBUS.  The address
     of this memory is given in the flags field in the configuration file.
     The first interface normally has its memory at Unibus address 0.

     Each of the host's network addresses is specified at boot time with an
     SIOCSIFADDR ioctl(2).  The ec interface employs the address resolution
     protocol described in arp(4) to dynamically map between Internet and Eth‐
     ernet addresses on the local network.

     The interface normally tries to use a “trailer” encapsulation to minimize
     copying data on input and output.	The use of trailers is negotiated with
     ARP.  This negotiation may be disabled, on a per-interface basis, by set‐
     ting the IFF_NOTRAILERS flag with an SIOCSIFFLAGS ioctl.

     The interface software implements an exponential backoff algorithm when
     notified of a collision on the cable.  This algorithm utilizes a 16-bit
     mask and the VAX-11's interval timer in calculating a series of random
     backoff values.  The algorithm is as follows:

	   1.	Initialize the mask to be all 1's.

	   2.	If the mask is zero, 16 retries have been made and we give up.

	   3.	Shift the mask left one bit and formulate a backoff by masking
		the interval timer with the smaller of the complement of this
		mask and a 5-bit mask, resulting in a pseudo-random number
		between 0 and 31.  This produces the number of slot times to
		delay, where a slot is 51 microseconds.

	   4.	Use the value calculated in step 3 to delay before retransmit‐
		ting the packet.  The delay is done in a software busy loop.

DIAGNOSTICS
     ec%d: send error.	After 16 retransmissions using the exponential backoff
     algorithm described above, the packet was dropped.

     ec%d: input error (offset=%d).  The hardware indicated an error in read‐
     ing a packet off the cable or an illegally sized packet.  The buffer off‐
     set value is printed for debugging purposes.

     ec%d: can't handle af%d.  The interface was handed a message with
     addresses formatted in an unsuitable address family; the packet was
     dropped.

SEE ALSO
     netintro(4), inet(4), arp(4)

HISTORY
     The ec driver appeared in 4.2BSD.

BUGS
     The hardware is not capable of talking to itself.	The software imple‐
     ments local sending and broadcast by sending such packets to the loop
     interface.	 This is a kludge.

     Backoff delays are done in a software busy loop.  This can degrade the
     system if the network experiences frequent collisions.

4.2 Berkeley Distribution	 June 5, 1993	     4.2 Berkeley Distribution
[top]

List of man pages available for 4.4BSD

Copyright (c) for man pages and the logo by the respective OS vendor.

For those who want to learn more, the polarhome community provides shell access and support.

[legal] [privacy] [GNU] [policy] [cookies] [netiquette] [sponsors] [FAQ]
Tweet
Polarhome, production since 1999.
Member of Polarhome portal.
Based on Fawad Halim's script.
....................................................................
Vote for polarhome
Free Shell Accounts :: the biggest list on the net