BSctx_set_si man page on DragonFly

Man page or keyword search:  
man Server   44335 pages
apropos Keyword Search (all sections)
Output format
DragonFly logo
[printable version]

BSctx_set_si(3)			 BlockSolve95		       BSctx_set_si(3)

NAME
       BSctx_set_si - Set whether or not inodes and cliques will be found

INPUT PARAMETERS
       context
	      - The context to change
       si     - if TRUE, then no cliques or inodes are found

RETURNS
       void

NOTES
       This  option allows more efficient execution when no cliques or i-nodes
       exist in the graph.  The default value is FALSE.

SYNOPSIS
       void BSctx_set_si(BSprocinfo *context, int si)

LOCATION
	BlockSolve95/src/BScontext.c

				  10/17/1996		       BSctx_set_si(3)
[top]